Laserfiche WebLink
Single Family Dwellin <br /> g <br /> Plan Review.Coinmerits <br /> l: F.F.E. shall'be,a minimum' .of 8" above,the road.elevation_and an engineered.site plan. <br /> '2.. :Lots shall-be graded.to comply,with R401.3 of the F.B:.C. .: , <br /> 3.: :Compaetionaest required_if 24" or more of fill dirt is brought in at any one place. . <br /> 4.::Tie in'.survey required before pouring concrete., <br /> 5_ Driveways:require a R.O.W. use permit: All.4:sides'of.driveway thru the sidewalk shall-have. : <br /> expansion matenal <br /> : :. <br /> 6. All setbacks ahall be met., <br /> .7. :Al-propertymarkers shall be uncovered and marked at time of first inspection: <br /> .8: :All A.D.A. requirements.shall be met.: . <br /> - 9.. No:electric;plumbing,.mechanical;,or framing shall be covered without an.inspection and <br /> approval-first.,. . <br /> 10.-All Garages shall,comply with section R302:6 of the F.B.C:(Fire Separation).. <br /> 11:Appliances shall not:be installed in a location where subject-to-mechanical darriage unless. <br /> :protected by approved barriers. M303.4 of the F.B.C. <br /> 12. Water heaters shall comply.with section.P607,3 of the F.B.C. <br /> 13. Foundation supports for A/C.units shall be raised at Least 31.1 above finished grade. M1308.1 <br /> 14. Return air in all_bedrooms. F.B.C. .M1620.4 . <br /> . 15. Smoke detectors are to be:installed:in accordance:with R313.1 of the.F.B.C. <br /> 16: All glazing requirements are to be in accordance with R308.4,of the F.B:C. - <br /> 17. All means of egress are to be in accordance with-R311::of the F.B.C., <br /> 18. `.`Green gypsum board" shall not be used:as a backer_iri:showers or tubs. R702:4:2.F.B.C. <br /> 19. Combination-type AFCI breakers are.reguired.at all,locations requiring-an AFCI,type breaker: <br /> 20. Carboni monoxide.alarms will.be required in.new:construction that uses fossil-burning heating <br /> :or appliances of an attached garage: They shall be,installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical,:and:electrical shall be separate from unit to:unit: This-includes all. . <br /> underground:plumbing and electric: <br /> 22, All 2011 N:E:C: Codes will be enforced: . <br /> 23:Tamper= Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C <br /> .24.:In accordance.with the Land Development:Code;lots.shall be. sodded before final of least 10, , <br /> feet'around the structure: <br /> 25.A.copy of the enerpp cacls shall be with permit at all'Hines. <br /> 26-Copy of fnal insulation f eport sliall b?-Provided with.petniit before.ftnab <br /> T.F.E.-Finished Floor Elevation <br /> F:B.C=Florida Building.Code 6th Edition <br /> R.O.W.-Right of Way <br /> A.D,A.-Americans with Disabilities Act N.E.C:-National Electric:Code(2011). . <br />