Laserfiche WebLink
s <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Aria 1672 Elev C Builder Name: DRH Express Home �. /� <br /> Street: �j� Z l,{l�(, S Permit Office: 1.[{�i �1 <br /> City,State,Zip: Zephyrhills, F l ``[a (,� Permit Number: <br /> Owner: _ �J I �`Y Jurisdiction: &It( 00 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 286.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 10.Ceiling Types (1672.0 sgft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(197.5 sgft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 334 <br /> a. U-Factor: Dbl,U=0.34 157.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13. Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.411 ft. <br /> Area Weighted Average SHGC: 0.316 14.Hot water systems <br /> 8. Floor Types (1672.0 sgft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> n AH�� <br /> Glass/Floor Area: 0.118 Total Proposed Modified Loads: 57.60 <br /> r <br /> Total Baseline Loads: 57.69 <br /> I hereby certify that the plans and specifications covered.by Review of the plans and a�ZHES7,q�� <br /> this calculation are in compliance with the Florida Energy specifications covered by this a �. 0 <br /> Code. calculation indicates compliance �w � <br /> with the Florida Energy Code. t~ rrrr: ';", cu,;�4,C0 <br /> PREPARED BY: L►11c Before construction is completed _ <br /> DATE: 11-9-17 this buildingwill be ins ected for <br /> p C7 t€i; <br /> compliance with Section 553.908 * °. <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Code. BCD4 <br /> OWNER/AGENT: v��. ', � BUILDING OFF CIAL: <br /> DATE: //'� /? DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. - <br /> 11/9/2017 10:27 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />