Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Ada 1.672 Elev C Builder Name: DRH Express Homes 612SI L LA <br /> Street: 1� Permit Office: <br /> ,� S F <br /> City,State,Zip: Zephyrhills, q1 Permit Number: <br /> Owner: - M6 ,\g Jurisdiction: <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> I. New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ft2 <br /> b.Frame-Wood,Adjacent R=1 1.0 286.00 ft2 <br /> 3. Number of units,if multiple family I c.N/A R= ft2 <br /> 4. 'Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1672.00 ft2 <br /> 6. Conditioned floor area above grade(W) .1672 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2, <br /> 7. Windows(I 97.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 334 <br /> a. U-Factor: DIJI,U=0.34 157.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: DIJI,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC; SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a..Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.411 ft. <br /> Area Weighted Averaqe SHGC: 0.316 14.Hot water systems <br /> Average <br /> 8, Floor Types (1672.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 . None <br /> c.NIA R= ft2 15,Credits Pstat <br /> Glass/Floor Area: 0.118 T.otal Proposed Modified Loads: -57.60 PASS <br /> Total Baseline Loads: 57.69 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 1,0113A <br /> specifications covered by this S71 <br /> this calculation are in compliance with the Florida Energy 0 <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: L Before construction is completed <br /> 6 <br /> DATE: 11-01-17 this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. <br /> OWNER/AGENT: BUILDING OFFICIAL' <br /> DATE: DATE: <br /> Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certifl6d,tact6ry-sealed in accordance' with R403.2.2.1. <br /> Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 11/9/2017 10:27 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />