Manual S Compliance Report Job: <br /> Wrightsofte p P Date: Oct 10,2014 <br /> Entire House BY: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FI-34668 Phone:727-847-3898 Fax:727-815-3399 Ucense:CAC033669 <br /> • ! ! <br /> For: DR Horton/Express Homes <br /> Lot 28 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> • iing, i i <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 21197 Btuh Entering coil DB: 76.1°F <br /> Outdoor design WB: 77.1 OF Latent gain: 2877 Btuh Entering coil WB: 63.0°F <br /> •Indoor design DB: 75.0°F Total gain: 24074 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CHI 4NB030****A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23532 Btuh 111%of load <br /> Latent capacity: 3786 Btuh 1320/o of load <br /> Total capacity: 27318 Btuh 113%of load SHR: 86% <br /> • •pipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 20312 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25625 Btuh 126%of load Capacity balance: 31 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm <br /> Output capacity: 6.4 kW 108%of load Temp. rise: 20 OF <br /> Meets are all requirements of ACCA Manual S. <br /> .A}F wri htsoft� 2017-Nov-1113:18:03 <br /> i. 't g .Right-SuiteO Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...on\wdghtsoft Files\Express homes\Ada 4EAB.rup Calc=MJ8 House faces: E <br />