Laserfiche WebLink
Building Analysis Job: 2575BI sf ADS carrier <br /> Date: 5/1/2018 <br /> lower floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Tampa International AP, FL, US Indoor temperature(OF) 70 75 <br /> Elevation: 10 ft Design TD (OF) 39 16 <br /> Latitude: 28°N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 <br /> Dry bulb(°F) 31 91 Infiltration: <br /> Daily range(OF) - 14 ( L ) Method Simplified <br /> Wet bulb (OF) - 77 Construction quality Semi-tight <br /> Wind speed(mph) 15.0 7.5 Fireplaces 0_ <br /> • <br /> Component Btuh/ft2 Btuh % of load <br /> Walls 5.5 5191 31.9 ucts <br /> Glazing 30.2 2683 16.5 nfiltrat°n <br /> Doors 21.2 432 2.7 wall <br /> Ceilings 1.7 60 0.4 <br /> Floors 4.1 4478 27.5 <br /> Infiltration 1.9 2039 12.5 <br /> Ducts 1400 8.6 <br /> Piping 0 0 Floors <br /> Humidification 0 0 Glazing <br /> Ventilation 0 0 Doors other <br /> Adjustments 0 <br /> Total 16284 100.0 <br /> Component Btuh/ft2 Btuh % of load <br /> Walls 2.8 2641 23.2 Internal Gains <br /> Glazing 56.3 5004 44.1 walls <br /> Doors 16.6 338 3.0 <br /> Ceilings 2.0 67 0.6 Ducts <br /> Floors 0 0 0 <br /> Infiltration 0.4 454 4.0 <br /> Ducts 1655 14.6 nfiltration <br /> Ventilation 0 0 other <br /> Internal gains 1200 10.6 Doors <br /> Blower 0 0 <br /> Adjustments 0 <br /> Total 11360 100.0 Glazing <br /> Latent Cooling Load= 1237 Btuh <br /> Overall U-value= 0.150 Btuh/ft2-°F <br /> Data entries checked. <br /> - wri-gF�tsoftm 2018-May-01 13:57:59 <br /> ^�^•r, w -w�•P� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ACCK ..ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces:NE <br />