Laserfiche WebLink
Buildin Anal SIS Job: 2575B1 sf ADS carrier <br /> g `y Date: 5/1/2018 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Tampa International AP, FL, US Indoor temperature(OF) 70 75 <br /> Elevation: 10 ft Design TD (OF) 39 16 <br /> Latitude: 280N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 <br /> Dry bulb(OF) 31 91 Infiltration: <br /> Daily range(OF) - 14 ( L ) Method Simplified <br /> Wet bulb(OF) - 77 Construction quality Semi-tight <br /> Wind speed(mph) 15.0 7.5 Fireplaces 0 <br /> • <br /> Component Btuh/ftZ Btuh % of load <br /> Walls 3.8 4204 32.8 °ds <br /> Glazing 30.2 2608 20.3 <br /> Doors 0 0 0 walls <br /> Ceilings 1.3 1868 14.6 nfil�v°n <br /> Floors 0 0 0 <br /> Infiltration 1.9 2299 17.9 <br /> Ducts 1846 14.4 <br /> Piping 0 0 <br /> Humidification 0 0 Ceilings <br /> Ventilation 0 0 Glazing <br /> Adjustments 0 <br /> Total 12825 100.0 <br /> • • IM <br /> Component Btuh/ft2 Btuh % of load <br /> ;Walls 2.7 3035 17.0 wall <br /> Glazing 53.0 4581 25.6 <br /> Doors, 0 0 0 Internal Gains <br /> Ceilings 1.7 2583 14.4 <br /> Floors 0 0 0 <br /> Infiltration 0.4 512 2.9 <br /> Ducts 2137 11.9 <br /> Ventilation 0 0 Glazing <br /> Internal gains 5040 28.2 Ducts <br /> Blower 0 0 <br /> Adjustments 0 Infiltration <br /> Total 17888 100.0 Ceilings <br /> Latent Cooling Load= 3041 Btuh <br /> Overall U-value= 0.083 Btuh/ftZ-°F <br /> Data entries checked. <br /> -=ightsoft- 2018-May-01 13:57:59 <br /> ^�^ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> ...ent%2575B sf ADS,template 1.5-2 ton Canrerrup Calc=MJ8 Front Door faces:NE <br />