My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19805
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19805
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2019 8:32:10 AM
Creation date
2/8/2019 8:32:08 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19805
Building Department - Name
LENNAR HOMES LLC
Address
3043 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Summary Job: 2575B1 sf ADS Carrier <br /> J Date: 5/1/2018 <br /> lower floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For:. Lennar Homes <br /> Notes: <br /> Design Information <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 39 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 14883 Btuh Structure 9705 Btuh <br /> Ducts 1400 Btuh Ducts 1655 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 16284 Btuh Use manufacturer's data y <br /> Rate/swing,multiplier 1.00 . <br /> Infiltration Equipment sensible load 11360 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 942 Btuh <br /> Ducts 294 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft') 1093 1093 Equipment latent load 1237 Btuh <br /> Volume(ft') 9654 9654 <br /> Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 12596 Btuh <br /> Equiv.AVF (cfm) 47 25 Req. total capacity at 0.85 SHR 1.1 ton <br /> Heating Equipment'Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC518AO0300 Cond 25HBC518AO0300 <br /> AHRI ref 9154643 Coil FB4CNP025L <br /> AHRI ref 9154643 <br /> Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER <br /> Heating input Sensible cooling 15300 Btuh <br /> Heating output 17700 Btuh @ 47'F Latent cooling 2700 Btuh <br /> Temperature rise 27 OF Total cooling 18000 Btuh <br /> Actual air flow 600 cfm Actual air flow 600 cfm <br /> Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh. <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.90 <br /> Capacity balance point= 30 OF <br /> Backup: <br /> Input=4 kW, Output= 15295 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wrightsoft® 2018-May-01 13:57:59 <br /> ^•�^•• ^•^- -� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ..ent\2575B sf ADS template 1.5-2 ton Canier.rup Calc=MJ8 Front Door faces:NE <br />
The URL can be used to link to this page
Your browser does not support the video tag.