Laserfiche WebLink
Project SI.11111171 Job: 2575B1 sf ADS Carrier <br /> J •y Date: 5/1/2018 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Proiect Information <br /> For: Lennar Homes <br /> Notes: <br /> Design Inf• • <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 39 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 10978 Btuh Structure 15751 Btuh <br /> Ducts 1846 Btuh Ducts 2137 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12825 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 17888 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2662 Btuh <br /> Ducts 379 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Coolingg (none) <br /> Area(ftz 1489 1489 Equipment latent load 3041 Btuh <br /> Volume(ft') 11912 11912 <br /> Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lit) 20929 Btuh <br /> Equiv.AVF(cfm) 53 29 Req. total capacity at 0.85 SHR 1.8 ton' <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9154943 Coil FB4CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER <br /> Heating input Sensible cooling 20400 Btuh <br /> Heating output 24000 Btuh @ 47'F Latent cooling 3600 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.062 cfm/Btuh Air flow factor 0.045 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.85 <br /> Capacity balance point= 16 OF <br /> Backup: <br /> Input= 3 kW, Output= 11787 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> Ad- wrightsoft® 2018-May-01 13:57:59 <br /> .'� .•- 1-^-- — Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> 14C4:�k ...entX2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces:NE <br />