Laserfiche WebLink
s <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes <br /> Street: 3051 Moulden Hollow Drive Permit office: City of Zephyrhills <br /> City,State,Zip: FL, Permit Number: <br /> Owner. Lennar Homes Jurisdiction:' 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d•N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1936.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features EF:0.950 <br /> b.N/A R= ftz None, <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.081 !1 <br /> Total Proposed Modified Loads: 62.46 PASS <br /> SS <br /> Total Baseline Loads: 62.81 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ' ks ` <br /> this calculation are in compliance with the Florida Energy specifications covered by this Off^ r <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. F.- jnri ��%% •=�'=.�'.;•�,�=0 <br /> PREPARED BY: Dave AulichBefore construction is completed <br /> DATE: this building will be inspected for I' F 7 <br /> compliance with Section 553.908 <br /> herebycertify that this building,as designed, is in compliance Florida Statutes. Ks <br /> fY 9� 9 � P <br /> with the Florida Energy Code. OZj`y <br /> OWNER/AGENT: MAY O 3 2018 BUILDING OF ICIAI <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires'an <br /> envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. <br /> 5/1/2018 12:22 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Pagel of 6 <br />