Laserfiche WebLink
2 <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941BI sf ADS Carrier Builder Name: Lennar Homes <br /> Street: 3051 Moulden Hollow Drive Permit Office: City of Zephyrhffls <br /> City,State,Zip: FL, Permit Number: t-?150-7 <br /> Owner., Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation I' Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 <br /> b.Frame-Wood,Adjacent R=1 1.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1936.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= W <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(157.3 scift.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ft2 <br /> SHGC; SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 <br /> c. U-Factor. Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.46 PASS <br /> Total Baseline Loads: 62.81 <br /> I hereby certify that the plans and specifications covered by Review of the plans and <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Da Ile OiCh Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes, <br /> with the Florida Energy Code. <br /> OWNER/AGENT:. MAY 0 3 2018 BUILDING OFFICIAL: <br /> DATE: - DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSIIRESNETIICC 380,is not greater than 0.030 Qn for whole house. <br /> 5/1/2018 12:22 PM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 <br />