Laserfiche WebLink
Single Family Dwelling <br /> Pla n Review.. omments <br /> 1; F.F-E.shall-'be a;zninimuri�:of 8" above.the road elevation and an engineered.site plan. <br /> . <br /> 2. Lots shall be'graded.to.corriply withR401.3 .of the F.B:C: <br /> 3. Compaction:test required.if 24" or more of fill dirt is brouglit in at any one place: <br /> 4: :Tie in surveyrequired before pouring concrete. <br /> 5. Driveways:require a R:(O:W. use permit:: All 4:sides of driveway.thru the sidewalk shall have <br /> expans,ion material.. <br /> 6- All,setbacks.shall be met.:: <br /> -7.. All.property:markers shall be,uncovered and iizarked.at time of first:inspection: <br /> .8. :All A.D.A:requirements shall be met. . <br /> 9. No:electric-'plumbing,.mechanical,,or framing shall be covered without an inspection.and <br /> approval first, <br /> 10. All Garages shall comply:with section R302;6,of the F.B.C.-(Fire S.eparation).. <br /> 11._Appliances shall not=be installed in.a location where subject to,mechanical'damdae unless <br /> protected byapproved barriers: M303.4 of the F.B:C <br /> 12. Water heaters shall_comply with section:P607.3 of the F.B.C: <br /> 13. Foundation'supports for A/C.units shall be raised at least 3" above finished-grade,. M1308.1 <br /> 14. Return air in altbedrooms,F.B.C. M1620:4 <br /> 15. Smoke detectors are.to be:installed:in accordan.ce.with:R31'3:1 of the:F.B.C. <br /> 16:.All glazing requirements are.to be in accordance with R308.4_of the.F.B:C. . <br /> 17. A11 means,of egress are to:be in accordance with R3 It of the F&C.. :: <br /> 18. "Green gypsum board"shall not be used as-a backer,in showers or tubs. R702:4>2:F.B.C; <br /> . . <br /> 19. Combination-type AFCI breakers.are,mouired at all locations requiring an AFCI.type breaker: <br /> - 20: Carbon monoxide aiarins will be required in riew:c' structionthat uses fossil-burning heating <br /> or appliances or an attached garage: They shall be.installed'ini accordancewith,the F.B.C. <br /> 21. All plumbing,mechanical,:and.electrieal shall:be separate from unit.to unit: This includes all <br /> underground plunribiiig acid electric: - <br /> 22. All 2011:N:E:C: Codes.will be-enforced: <br /> 23. Tamper=Resistant Receptacles in accordance wvith 40.6.11 of the 2011 ME:C <br /> 24:.Iri accgrdance_ivith the Land Development:Code' lots.shall be sadded'before final at least-10 <br /> feet::around the structure. <br /> ZS R copy ofthe enemy eacZs shall be with pertnit-t t all dines <br /> 26. Copy of r1nal insulation report shall be.provided with.peMiit_beforel"ha <br /> F.F:E.-Finished Floor Elevation <br /> F.B:C- Florida Building Code 6t'Edition <br /> R:O.W-Right:of Way , <br /> A.D.A.-Americans with Disabilities Act : N.E.C.-National Electric Code (2011). <br />