My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19658
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19658
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2019 11:52:33 AM
Creation date
2/27/2019 11:51:58 AM
Metadata
Fields
Template:
Building Department
Company Name
CRESTVIEW HILLS
Building Department - Doc Type
Permit
Permit #
18-19658
Building Department - Name
RAKOCY,FRANKLIN & PLUMMER SHANNON
Address
7553 WEEHAWKEN DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Snow Load 0-20 psf <br /> Modules In Landscape - <br /> Wind 3 eed. Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE.?10 Category Zone 1. Zone 2 Zone 3 Zone T Zone 2 Zone 3 <br /> B 159 93- . _59 } NOW <br /> 85 mph 1.10 mph • C . 114 67 42 - 88 88- - <br /> D 96 56 35 -91. 74 74 <br /> B 146 85 54 <br /> 90 mph 115 mph . C 104 61 38 98 so 80 <br /> D 68 51 32 . .83 68 68 <br /> B - 123 72 . 45 95 95 <br /> 100•mph 125 mph Q 8s 51 32- 83 68 68 <br /> D 74 43 _ 27 70- 57 57 <br /> B 98 57 36 93 76 76 <br /> 110 mph 140 mph C 70 41 26 66 54 54 <br /> D 59 34 22 56 46 46 <br /> B . 85 50 31 89 66 -66 <br /> 120 mph ISO mph C 61 36:- 22. 58 47 47 <br /> D 51- 36 19 49-. _ . 40 40: <br /> Notes: <br /> ®Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to.meet appropriate rafter spacing <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" <br /> 3.)Maximum allowed standoff capcity=5470(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of 40" <br /> 6.)Based on Risk.Category 11(ASCE 7-10)structures less than 30 feet in height <br /> 7.)Ail adjustment factors are set to 1.No site specific engineering is included 1.n this table <br /> Snow Load 0-20 psf <br /> .Wind Speed Exposure 2:12.<Roof Pitch<6.12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10 CategoiV Zone 1 Zone 2 Zone 3 Zone 1. Zone 2 Zone 3 . <br /> - - - B 91 '53 33 <br /> 85 mph 110 mph C 65 38 24 61 50 . 50 <br /> _D 55 32 _. 20 _ - .52 42 -42 <br /> B 83 49 30 - <br /> 90 mph 115 mph C 59 35 22 56 46 46 <br /> D 50 29 18 47 38 38 <br /> - - - - _.. <br /> B --; <br /> 100 mph ! 125 mph C 50 29 18 47 39 39 <br /> p• 42-_•_ 15 '40_ 32- - = 32 -. . <br /> B 56 33 20 53 43 43 <br /> 110 mph 140 mph C 40 23 14 38 31 31 <br /> D 34 19 12 32 26 26 <br /> 13 49 28 18 4B 37 37 <br /> 120 mph 150 mph C 35 20 12 33 27 27 <br /> D 29 17_ 10 28 22. 22 <br /> Notes: . <br /> -Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EccFasten Solar standoff <br /> 2.)Maximum allowed spacing approved by EcbFasten Solar is 48' <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module length of 70" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less then 30 feet In height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is Included In this table <br /> www.ecofastensolarcom info@ecofastensolar.com 877-859-3947 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.