My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18254
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18254
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 9:03:20 AM
Creation date
5/23/2019 8:46:46 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM
Building Department - Doc Type
Permit
Permit #
17-18254
Building Department - Name
ADVENTIST HEALTH SYSTEM
Address
7350 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TFP172 <br /> Page 2 of 4 <br /> Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 <br /> 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. <br /> 2 - Button 5 - Compression STYLE 15 or 20 <br /> 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED <br /> Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON <br /> 6* I <br /> 5 7/1(11,1 mm) <br /> 4 NOMINAL 2" <br /> MAKE-IN (50,8 mm) <br /> 2 2" 11 I <br /> 3 (50,8 mm) (34,9 mm) <br /> WR 11 ENCH <br /> / FLATS <br /> 1 <br /> 1/2 NPT** DEFLECTOR* �— 2-7/8"(73,0 mm)DIA. <br /> CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT <br /> FIGURE 1 <br /> SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS <br /> 5.6 K-FACTOR, 112 INCH NPT, QUICK RESPONSE <br /> Operation Installation <br /> The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, <br /> WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) <br /> (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- <br /> END"A") fluid expands sufficiently to shatter the dance with this section. <br /> glass bulb, allowing the sprinkler to General Instructions <br /> FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if <br /> W-TYPE 6 the bulb is cracked or there is a loss <br /> SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- <br /> kler held horizontally, a small air bub- <br /> WRENCH Criteria ble should be present. The diameter <br /> of the air bubble is approximately 1/16 <br /> RECESS The TYCO Series TY-FRB,5.f K-factor, inch(1,6 mm)for the 135°F(57°C)and <br /> Upright(TY313) and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) <br /> Sprinklers are intended for fire protec- temperature ratings. <br /> tion systems designed in accordance <br /> with the standard installation rules rec- A leak-tight 1/2 inch NPT sprinkler joint <br /> should be obtained b applying a min- <br /> Approval by the applicable Listing or imum to maximum torque f to 14 <br /> Approval agency(such as, UL Listing ft.-Ibs. (9,5 to mu Nm her levels <br /> is based on the requirements of NFPA of torque can distort the sprinkler l Inlet <br /> 13, and FM Approval is based on the <br /> requirements of FIVI's Loss Prevention with consequent leakage or impairment <br /> PUSH WRENCH Data Sheets).Only the Style 15 or Style of the sprinkler. <br /> INTO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for <br /> ENGAGEMENT WITH SPRINKLER for recessed pendent installations. insufficient adjustment in the Escutch- <br /> WRENCHING AREA eon Plate by under-or over-tightening <br /> the sprinkler. Re-adjust the position of <br /> FIGURE 3 the sprinkler fitting to suit. <br /> W-TYPE 7 RECESSED <br /> SPRINKLER WRENCH Upright and Pendent Sprinklers <br /> The Series TY-FRB Upright and Pen- <br /> dent Sprinklers must be installed <br /> in accordance with the following <br /> instructions. <br /> Step 1.Install Pendent sprinklers in the <br /> pendent position. Install upright sprin- <br /> klers in the upright position. <br /> Step 2. With pipe-thread sealant <br /> applied to the pipe threads, hand- <br /> tighten the sprinkler into the sprinkler <br /> fitting. <br />
The URL can be used to link to this page
Your browser does not support the video tag.