Florida Building'Code, Energy Conservation, 6th, Edition (2017) <br /> .Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods <br /> ADDRESS: Permit Number: <br /> FL. <br /> MANDATORY REQUIREMENTS See individual code sections for full details. <br /> SECTION'11401 GENERAL <br /> R401.3 Energy Performance Level(EPL)display card(Mandaiory)lhe building official shall require that an energy performance level(EPL)display <br /> card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law(Section <br /> 553.9085,Florida Statutes)requires the EPL display;card to be Included as an addendum to each sales contract for both presold and nonpresold <br /> residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components Installed In a <br /> dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and <br /> specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can tie found in Appendix RD. <br /> R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air.leakage In accordance.with the requirements of <br /> Sections R402.4.1 through R402.4.5. <br /> Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to <br /> comply with Section C402.5. <br /> R402A.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The seating <br /> methods between dissimilar materials shall allow for differential expansion and contraction. <br /> R402.4.11.11 installation The components of the building thermal envelope as listed In Table R402,4.1.1 shall be installed in accordance with <br /> the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the <br /> code official,an approved third party shall Inspect all components and verify compliance. <br /> 111402.4.11.2'restIng. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air <br /> changes per hour In Climate Zones i and 2,and three'air changes per hour in Climate Zones 3 through 8.Testing shall be co.nducted In <br /> accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either <br /> individuals as defined In Section 553.993(5)or(7),Florida Statutes,or Individuals licensed as set forth in Section 489.105(3)(f),(0)or(I)or <br /> an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code <br /> official.Testing shall be performed at any time after creation of all penetratlons'of the building thermal envelope. <br /> Exception- Testingil <br /> is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing <br /> buildings in which the new construction is less than 85 percent of the building thermal envelope. <br /> During testing: <br /> 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended <br /> weatherstripping or other Infiltration control measures. <br /> 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond <br /> Intended infiltration control measures. <br /> 3. Interior doors,if installed at the time of the test,shall be open. <br /> 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5. Heating and Cooling systems,if installed at the time of the test,shall be turned off. <br /> 6. Supply and return registers,if Installed at the time of the test,shall be fully open. <br /> R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using <br /> right-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the <br /> fireplace.Where using fight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. <br /> R402.4.3 Fenestration air lealkageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per <br /> square foot(1.6 Lls/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or <br /> AAMA/WDMAICSA 101/l.S.2/A440 by an accredited,Independent laboratory and listed and labeled by the manufacturer. <br /> Exception: Site-built windows,skylights and doors. <br /> 1/5/2016 11:57 AM EnergyGauge@ USA-FlaRes2017 FBC 6th Edition(2017) Complia Page 1 of 5 <br />