My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19439
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19439
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 9:31:56 AM
Creation date
5/23/2019 9:31:54 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-19439
Building Department - Name
WILLHOIT,BETTY JANE
Address
5911 17TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-� �� ' <br /> a a a Gulf o r - , <br /> ' 111mmok SUPPLY & MANUFACTURING <br /> ' y,.._., TM <br /> GULFK <br /> L ' • GUAGE GULFRIBTM <br /> PANEL OVER 15/32" PLYWOOD <br /> ♦ F <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2017, Sections 1504.3.2. <br /> Product Description: GulfRibTM, 3/a" Rib Roof Panel, Minimum 29 Ga. Steel, 36" Coverage, 1 <br /> through fastened roof panel over minimum 75/3z" Plywood Decking. Non Structural <br /> application. <br /> Panel Material/Standards: Material: Minimum 29 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to <br /> Florida Building Code 2017 Section 1507.4.3. <br /> Paint Finish Optional <br /> Yield Strength: Min. 80.Oksi <br /> Corrosion Resistance: Panel Material shall comply with Florida Building <br /> Code 2017, Section 1507.4.3. <br /> Panel Dimension(s): Thickness: 0.0142" Minimum <br /> Width: 36" Coverage <br /> Rib Height: 3/a" Major Rib at 9" O.C. <br /> Panel Fastener: #9-15xl.5" HWH with sealing washing or approved equal <br /> 1/4" minimum penetration through plywood. <br /> Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 <br /> Substrate Description: Minimum 75/32" thick, APA Rated plywood over supports at maximum 24" O.C. <br /> Design of plywood and plywood supports are outside the scope of this <br /> evaluation. Must be designed in accordance w/Florida Building Code 2017. <br /> Design Uplift Pressures: Table"A" <br /> =kAa, mum ,fJ;pli�;.Deer ress re 71 76 psf <br /> Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- <br /> 2.5"6.5"-2.5"-6.5" <br /> F er ee c 4 <br /> .' tt Ipacln.g- <br /> ; e. <br /> Design Pressure includes a Safety Factor=2.0. <br /> I <br /> FL#11651.26 R3•OCTOBER 5,2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.