Laserfiche WebLink
I Not GuIfCar <br /> y R �!' <br /> SUPPLY & MANUFACTURING <br /> RIMRh TM <br /> GULFRID <br /> ■TM PANEL OVER 15/32" • • <br /> 3� <br /> t? FLORIDA <br /> ■ , PRODUCT <br /> ■ • , APPROVAL <br /> ■ ■ • - • ,■ ■ <br /> T hi1 <br /> Code Compliance: The product described herein has demonstrated compliance with the <br /> Florida Building Code 2017, Sections 1504.3.2. <br /> Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load <br /> requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. <br /> Performance Standards: The product described herein has demonstrated compliance with: <br /> • UL 580-06-Test for Uplift Resistance of Roof Assemblies <br /> • UL 1897-12- Uplift Test for Roof Covering Systems. <br /> • FM 4471-1992, Section 4.4 Foot Traffic Resistance Test <br /> Reference Data: 1. UL 580-94/1897-98 Uplift Test <br /> Force Engineering &Testing, Inc. (FBC Organization #TST-5328) <br /> Report No. 1 17-0033T-05 & 1 17-0331T-08D, Dated 05/05/05 &07/09/08 <br /> 2. FM 4471-95, Section 4.4 Foot Traffic Resistance Test <br /> Force Engineering &Testing, Inc. (FBC Organization #TST-5328) <br /> Report No. 117-0238T-09E, Dated 07/21/2009 <br /> 3. Certificate of Independence <br /> By Dan Kuhn, P.E. (FL#75519)Q Kuhn Engineering, LLC <br /> (FBC Organization #ANE ID: 10743) <br /> Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. <br /> 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test <br /> standard. <br /> 3. The FM 4471-95 test standard is equivalent to the FM 4471-1992 test <br /> standard. <br /> Quality Assurance Entity: The manufacturer has established compliance of roof panel products in <br /> accordance with the Florida Building Code and Rule 61 G20-3.005(3)for <br /> manufacturing under a quality assurance program audited by an approved quality <br /> assurance entity. <br /> Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including <br /> Section 1507.4.2 and in accordance with Manufacturers recommendations. For <br /> slopes less than 3:12, lap sealant must be used in the panel side laps. <br /> Installation: Install per Manufacturer's recommended details. <br /> Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. <br /> FL#11651.26 R3•OCTOBER 5,2017 <br /> I MIZEMSSIZZML <br /> 1200 CLINT MOORE ' BOCA RATON, • • #30464 <br />