Laserfiche WebLink
FLUKIUA t:Nr-K%2 T Mrri%oilr-iv%o i <br /> FOR BUILDING CONSTRUCTION <br /> • Envelope Leakage Test Report <br /> Prescriptive and Performance Method <br /> Project Name: SILVERADO Builder Name: D R HORTON <br /> Street: 6540 Wagon Trail St Permit Office: <br /> City,State,Zip: Zephyrhills,FL 33541 Permit Number: <br /> Design Location: 6540 Wagon Trail St(Lot 14) Jurisdiction: <br /> Cond.Floor Area: 1751 Cond.Volume: 16409 <br /> Envelope Leakage Test Results Leakage Characteristics <br /> Regression Data: <br /> C: n: R: <br /> CFM(50): 1580 <br /> Single or Multi Point Test Data ELA: 87 <br /> HOUSE PRESSURE FLOW: <br /> 1 50 Pa 1580 cfm EqLA: 205 <br /> ACH: 6.15 <br /> 2 0 Pa 0 cfm <br /> SLA: .05 <br /> 3 0 Pa 0 cfm <br /> 4 0 Pa 0 cfm ACH(50)*: 6.15 <br /> For prescriptive projects,tested leakage must be<=7 <br /> 5 0 Pa 0 cfm ACH(50). For performance projects,tested leakage <br /> must be—the ACH(50)shown on Form R405-2014 <br /> 6 Pa cfm for this project. <br /> R402A.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7air changes per hour In Climate Zones I <br /> and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in <br /> Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the <br /> results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all' <br /> penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration <br /> 3.Interior doors,if installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off,and <br /> 6.Supply and return registers,If installed at the time of the test,shall be fully open. <br /> I hereby certify that the above envelope leakage performance results <br /> demonstrate compliance with Florida Energy Code requirements in <br /> accordance with Section R402.4.1.2. <br /> Testing shall be conducted by either individuals as <br /> defined in Section 563.993(5)or(7),Florida Statutes -fkamE S <br /> or individuals licensed as set forth in Section <br /> 489.106(3)(f),(g),or(I)or an approved third party.A <br /> written report of the results of the test shall be signed <br /> Dititally signed by Michael by the third party conducting the test and provided to <br /> Silberstein the code official. <br /> Date:2018.11.29 16:07:46 EST <br /> CN=Michael Silberstein,O=TopBuild <br /> Home Services,01-1, WrA <br /> EMAILADDRESS=Mlchael.Sliberstei <br /> Signature: n@topbuild.com,C=US <br /> Printed Name: Michael Silberstein BUILDING FF IAL:l <br /> Date: 11/29/2018 DATE: f Cs <br /> Thank you for allowing TopBulld the opportunity to provide the above services for you.Please feel free to contact me with any questions. <br /> 1012512017 406068 <br />