Laserfiche WebLink
Single Family:Dwelling: <br /> Pl <br /> an <br /> an RevieW Comments <br /> 1: F.F.E. shall be a minimum:of.8" above.the road.elevation and an engineered.site plan. . . <br /> 2- Lots shall be-graded to comply with R401.3 of the F.B.C. . <br /> I. Compaction test required if 24" or more:of fill dirt_ is brought in at any one place. <br /> 4:. :Tie in-survey required before pouring concrete.. <br /> 5. Driveways require a R.O.W.use permit: All 4.sides of driveway thrd the sidewalk shall'have, <br /> expansion material:. <br /> 6.. All setbacks shall be met:. . <br /> 7. .All property markers shall be uncovered and marked at time of first 'inspection: <br /> .. <br /> 8. All A.D.A. requirements shall be met.:- <br /> 9. No:electric, g P lumbin ,mechanical..or frainiri shall be covered without an,ins ection-arid <br /> approval first. <br /> 10. All Garages shall.comply:with,section R302:6 of the F.B.C. (Fire Separation).. <br /> 11.Appliances;shall not:be iristallecl in.a location where subject to mechanical damage unless. :_ <br /> protected by approved barriers. M303.4 of the F.B:C <br /> 12. Water heaters shall comply with sectionT607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade..' M1308.i. <br /> 14.Return air in all:bedrooins..F.B.C. M..1620.4.: - <br /> 15. Smoke detectors are Io' be installed:in accordance.with:R313:1 of the:F.B.C. <br /> .16: All glazing requirements uirements are..to bein accordance with R308.4.of the F.B.C. <br /> 17. Al_1 means of egress are to be in accordance with R31 l:of the F;B.G., ' <br /> 18. "Green gypsum.board shall not be'.used:as a backer iri hoovers or tubs. R702.4:2 F.B.C. <br /> . . . <br /> 19.-Combination-typeAFCl breakers are,required at all.locations requiring.dn AFCI,type breaker: <br /> .20. Carbon monoxide alarins:will.be required in new:construction that uses fos'sil-bunting heating <br /> or appliances or an attached garage.: They shall be-installed in accordance with.the F.H.C. . <br /> 21. All lumbin mechanical .and:electrical shall be:se arate from unit to:unit: This includes all. . <br /> p. . gI.. : . p. <br /> underground plumbing and electric: <br /> 22. All 2016:ME.C;. Codes.will be enforced. . <br /> 23. Tamper- Resistant Receptacles 1n accordance'-with 406.11 of the 2016 N.E:C <br /> 24-An accordance..with.the Land.Development.Code;lots.shall be sodded before f nal of least 10: . <br /> feet around the structure. <br /> 25. Blower door:test and blown in insulation'card shall be provided before C.O.. <br /> 26 A cony ofthe energy cacls shall be with permit_at-all tines. <br /> 27.. Copy of final insulation report shall be:pi�ovided with:perjnit before finaL <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition . <br /> R.O.W.-Right ofWay <br /> A.D.A:-Americans with.DisabilitiesAct N.E.C.-National Electric Code(2011) <br />