Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Galen 2432 Elev D Builder Name: DRH Express Homes <br /> Street: Permit Office: A� 4 $ <br /> City,State,Zip: Zephyrhills, L,c + �I�} Permit Number: 1 -I�13 <br /> Owner: ` (�'I ` 1 Jurisdiction: (9 tt(B c <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2511.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a. Frame-Wood,Exterior R=11.0 1269.30 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 956.22 ftz <br /> 3. Number of units,if multiple family 1 c. Frame-Wood,Adjacent R=11.0 286.00 ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? No 10.Ceiling Types (1451.0 sgft.) Insulation Area a. Under Attic(Vented) R=30.0 1451.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 2432 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c. R= ftz <br /> 11. Duct <br /> s R ftz <br /> 7. Windows(229.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 231 <br /> a. U-Factor: Dbl,U=0.34 189.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a. Electric Heat Pump 33.8 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.585 ft. <br /> Area Weighted Average SHGC: 0.315 14. Hot water systems <br /> 8. Floor Types (1451.0 sg a.Electric Cap:50 gallons <br /> ft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1019.00 ftz b. Conservation features <br /> b.Floor over Garage R=19.0 432.00 ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.094 /'1�7�7 <br /> Total Proposed Modified Loads: 74.14 PASS <br /> Total Baseline Loads: 74.48 <br /> I hereby certify that the plans and specifications covered by Review of the plans and - STr�? <br /> this calculation are in compliance with the Florida Energy specifications covered by this � p� <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Q Before construction is completed r t, <br /> DATE: Il-v-n this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. SOD WE <br /> OWNER/AGENT: - BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. - <br /> = Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Gin for whole house. <br /> 11/9/2017 10:47 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />