My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19973
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19973
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 11:04:21 AM
Creation date
5/23/2019 11:04:19 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19973
Building Department - Name
DR HORTON INC
Address
6501 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM'R405-2014 <br /> FLORIDAENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida.Department of Business and Professional Regulation - Res'idential Performance Method <br /> Project Name: Galen 2432 Elev D Builder Name: DRH Express Homes <br /> Street: -L50 1 ' Permit Office: <br /> City,State,Zip: Zephyrhills, FL,c, 5t �1 Permit Number: <br /> Owner: LI' ` l Jurisdiction: <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2511.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1269.30 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 956.22 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 286.00 ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1451.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1451.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2432 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c. R= ft2 <br /> 11.Duct <br /> s R ft2 <br /> 7. Windows(229.0 sqft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 231 <br /> a. U-Factor: Dbl, U=0.34 189.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 33.8 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.585 ft. <br /> Area Weighted Average SHGC: 0.315 14. Hot water systems <br /> 8. Floor Types (1451.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1019.00 ft2 b. Conservation features <br /> b.Floor over Garage R=19.0 432.00 ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 74.14 PASS <br /> Glass/Floor Area: 0.094 0� <br /> Total Baseline Loads: 74.48 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0I'VfmS ?� <br /> this calculation are in compliance with the Florida Energy specifications covered by this = p <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. ti XrJr '�: • r �4;, O <br /> PREPARED BY: L^& Before construction is completed w -•i ' ''- <br /> DATE: n-a-n this building will be inspected for <br /> C9 Iil �, <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. �S <br /> with the Florida Energy Code. <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> = Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 11/9/2017 10:47 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.