My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19977
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19977
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 11:07:10 AM
Creation date
5/23/2019 11:07:09 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19977
Building Department - Name
LENNAR HOMES LLC
Address
3136 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 1791A1 sf ADSDate: 5/1/2018 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 22079 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.3°F Latent gain: 3075 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 25155 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 24140 Btuh 109% of load <br /> Latent capacity: 4260 Btuh 139% of load <br /> Total capacity: 2840d Btuh 113% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss:' 25667 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC530AO0300+FX4DNF031L <br /> Actual airflow: 1000 cfm <br /> Output capacity: 22528 Btuh 88% of load Capacity balance: 30 °F <br /> Supplemental heat required: 3139 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1000 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets all requirements of ACCA Manual S. <br /> 4y Wrightsoftm 2018-May-0110:17:07 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> 14C3:;k ...uipment\1791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces:NW <br />
The URL can be used to link to this page
Your browser does not support the video tag.