Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments: <br /> l: F.F:E. shall be:a minimum:of.8" above.the road.elevation and an engineered.site plan. <br /> -2. Lots shallbe graded.to,comply with R401.3 of the F.B.C. <br /> 3.: Compaction test required.if 24" or more of fill dirt is brought in at any one place: <br /> 4: :Tie in survey required before'pourin9 concrete. <br /> 5.. _ Driveways:require a R:O.:W, use permit:: All 4:sides of.driveway.thru the sidewalk shall have. <br /> expansion matenal:. <br /> 6. All, setbacks.shall be met.: <br /> -7.: All property:markers shall be.uncovered and marked at time'of first 'inspection: <br /> :.8:. :All A.D.A.requirements shall be met.: <br /> 9. No electric;plumbing,=mechanical; or(raining shall be:be without an,inspection and <br /> approval first. <br /> 10. All Garages shall_comply.with section R3 02;6:of the.F.B.C.--(Fire S:eparation).. <br /> 11. Appliances:shall not be installed in a location where subjectto mechanical damage unless. <br /> protected by approved barriers. M303.4 of.the F.B:C <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for,A/C units shall be raised`at least 3' above finished grade.. M1308.1 : <br /> 1-4. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15: Smoke detectors are to be installed:in accordance:with R313:1 ofthe F.B.C. <br /> - 16.: All glazing requirements are.to be in accordance with R308.4,of the.F.B.C. <br /> 17. All means_of egress are to:be in:accordance with R311.of the RB.C.. :. <br /> 18. `.`Green gypsum.board"shall riotbe used:as a backer.in showers or tubs. R702.4:2.F.B.C. <br /> 19. Combination-type AFCI breakers are.required:at all locations requiring an AFCI,type breaker: <br /> 20. Carbon-monoxide alarms will be required in.new construction.that uses,fossil-burningheating <br /> or appliances or an attached garage: They shall be installed in accordance with the F.B.C.- . <br /> . .21. All plumbing, mechanical,:and:electn al shall.be separate from unit to:unit: This includes all, <br /> underground plumbing and electric: <br /> 22.=A11201-6.N.E:C: Codes will be enforced.. <br /> 23. Tamper= Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24-Ah accordance:.with the Land..Development:Code, lots.shall be sodded before final at least 10. . <br /> feet around the structure. . . <br /> 25. Blower door=test and blown in irisulation card shall,be provided before C:.O.- <br /> 26_A copy of"the energy cacls shall be with-permit at all times; - <br /> 2 Z Copy of r1nal insulation report shall be:provided.ivitli:permit before finab . <br /> F.F:E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-Right of-Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-.National Electric Code(2011) <br />