Laserfiche WebLink
Manual S Compliance Report Job: 2575A1 sf ADS Carrier <br /> Date: 511/2018 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project Information <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 17774 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.2°F Latent gain: 3317 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21091 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 115% of load <br /> Latent capacity: 3600 Btuh 109% of load <br /> Total capacity: 24000 Btuh 114% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 32.1°F Heat loss: 12662 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 24000 Btuh 190% of load Capacity balance: 17 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model <br /> Actual airflow: 800 cfm <br /> Output capacity: 3.5 kW 93% of load Temp. rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> i <br /> - wrightsoft® 2018-May-01 09:12:05 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 <br /> AOM Page 2 <br /> ...ment12575A sf ADS template 1.5-2ton Canier.rup Calc=MJ8 Front Door faces: W <br />