My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20160
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20160
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:40:44 PM
Creation date
5/28/2019 2:40:39 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20160
Building Department - Name
LENNAR HOMES LLC
Address
3019 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 1941B1 sf ADS Carrier <br /> Date: 7/26/2018 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> project Inf• <br /> For: Lennar Homes <br /> • •-fing quipm <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 26187 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 4080 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 30267 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29580 Btuh 113% of load <br /> Latent capacity: 5220 Btuh 128% of load <br /> Total capacity: 34800 Btuh 115% of load SHR: 85% <br /> H. <br /> gratingsgq up en <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 27641 Btuh Entering coil DB: 69.77 <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Output capacity: 26331 Btuh 95% of load Capacity balance: 26 OF <br /> Supplemental heat required: 1310 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 OF <br /> Meets all requirements ofACCA Manual S. <br /> -Fp- wrightsoft, 2018-Jul-26 12:40:29 <br /> 1. 1-1-1-...=11-Y.. Right-Suite®Universal 2018 18.0.16 RSU05714 <br /> ACCP, Page 1 <br /> ...equipment\1941 sf ADS template 3ton Cartier.rup Calc=MJ8 Front Door faces:NE <br />
The URL can be used to link to this page
Your browser does not support the video tag.