My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20165
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20165
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:44:08 PM
Creation date
5/28/2019 2:44:06 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20165
Building Department - Name
LENNAR HOMES LLC
Address
3232 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1^ <br /> Project Summary Job: 1551B1 sf ADS Carrier <br /> J ry Date: 7/25/2018 <br /> Entire House By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project Information <br /> For: Lennar Homes <br /> Notes: FBC 2017 <br /> Design Information <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 39 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 19893 Btuh Structure 16807 Btuh <br /> Ducts 1901 Btuh Ducts 2200 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 21794 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 19007 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2302 Btuh <br /> Ducts 390 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2 1555 1555 Equipment latent load 2692 Btuh <br /> Volume(ft') 12700 12700 <br /> Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 21699 Btuh <br /> Equiv.AVF (cfm) 55 30 Req. total capacity at 0.85 SHR 1.9 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9154943 Coil FB4CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER <br /> Heating input Sensible cooling 20400 Btuh <br /> Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point= 30 OF <br /> Backup: n/a n/a <br /> Input= 0 kW, Output= 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> A- wrightsoft- 2018-Jul-25 07:31:48 <br /> ^�^•� • �� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ACCK ..equipment\1551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.