Laserfiche WebLink
Manual S Compliance Report Job: 1551B1 sf ADS Carrier <br /> Date: 7/25/2018 <br /> Entire House By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project Information <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 19007 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.3°F Latent gain: 2692 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21699 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 107% of load <br /> Latent capacity: 3600 Btuh 134% of load <br /> Total capacity: 24000 Btuh 111% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 21794 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 18304 Btuh 84% of load Capacity balance: 30 °F <br /> Supplemental heat required: 3490 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 800 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets all requirements of ACCA Manual S. <br /> -Fk- wrightsoft- 2018-Jul-25 07:31:48 <br /> I Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ACCK ...equipment11551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces: W <br />