Laserfiche WebLink
PHOTOVOLTAIC SYSTEM APPROVAL CERTIFICATE <br /> AWARDED TO: CERTIFICATION#: DJ-17-02907 <br /> FSEC <br /> 1 A CEDGreentech DESIGNATION: SMAS3Zr Inverter-Hyundai HiS-S29OROModules <br /> 1 \� 2460 12th St SYSTEM SIZE: 8,990 Wdc <br /> Sarasota,FL 34237 DATE: 2017-10-23 <br /> http://cedgreentechfi.com/ EXPIRATION: 2022-10-23 <br /> Module Manufactuer Module Model FSEC Registration Number Strings' Shortest String` Longest String` Total <br /> Hyundai Heavy Industries Green En HiSS290RG HH17-NT90-0134 3 10 11 31 <br /> I <br /> •torcyetevo using ACW modulesorme—dera,Wsdata reAeda bench ch to ratherdmn0tvs <br /> Inverter Manufacturer Inverter Model Min.Input Voltage Max.Input Voltage Max DC Input AC Power Rating Output Voltage <br /> SMA SB7.7-1SP-US-40 100 V 550 V 7,950 W 7,680 W 208/240 V <br /> Charge Controller Manufacturer Charge Controller Model Battery Manufacturer Battery Model IBattery Type Capacity(C/20 rate) JQuantity <br /> N/A N/A N/A N/A N/A N/A WA <br /> Review Comments <br /> Inspection <br /> Electrical Design(Verify the following items for agreement between the installed components and the supplied electrical schematic.) <br /> ❑Size,type and location of all conductors in the PV system; <br /> ❑Conduit,raceways,junction boxes,and combiner boxes; <br /> o Size,current rating,voltage ratings,and location of all over-current protection devices; <br /> ❑Rating and location of all disconnects; <br /> ❑Point of connection to the utility; <br /> o PV module and equipment grounding system(including conductor size); <br /> 1 ❑PV DC circuit and system grounding(including grounding electrode conductor size); / <br /> / ❑Ground fault detection&interrupter(GFOI)rating and location; I� <br /> ❑Battery wiring and cable sizes(if applicable). i <br /> Inspector Name(printed) Inspector Signature Date <br /> '.I <br /> Installer Information and Certification <br /> Company Name: Website: <br /> Address: Phone Number: <br /> Florida Contractor License Number. <br /> Florida Contractor License Type: <br /> 1 ❑Solar ❑Electrical ❑Other,please specify: }� <br /> I hereby certify that this PV system has been installed in full accordance with the National Electrical Cade. <br /> Installer Name(printed) Installer Signature Date <br /> Note: FSEC approvals do not replace or exempt any requirements of electrical utilities or local jurisdiction authorities in matters such as permitting,inspections,or utility interconnection <br /> agreements as required for PV system installations. When referring to FSEC approvals in any documentation produced by the supplier,including technical or marketing information,the fallowing <br /> statement shall be included: <br /> 'The photovoltaic system design described in this manual,when property installed and maintained,meets the <br /> minimum recommended practices established by the Florida Solar Energy Center. This approval'does not imply <br /> endorsement or warranty of this product by the Florida Solar Energy Center or the State of Florida." <br /> i <br /> Solar Testi 9r Certification oordinator <br /> Standard�203 <br />