My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20405
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20405
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:23:10 AM
Creation date
6/4/2019 7:23:09 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20405
Building Department - Name
LENNAR HOMES LLC
Address
39615 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building and Construction Services(BCS) <br /> PA <br /> COUNTY FLORIDVA Blower Door Test Report Form <br /> Property Address:�3 L I Unit N: <br /> S <br /> Permit#: 0 0 A 1� Testing Company Name- SKYMC <br /> -4%-/ _3 <br /> Test Date: <- j"<,!!,o Tesaeuwe:HASSEN KHELIFI <br /> TesterCert#- MY3YG6 Conta<t Phone-904-903-1076 <br /> E,.u-hkhelifi@skyetec.com <br /> 402.4.1.2 Testino,,. Building envelope air tightness shall be demonsta-ated.by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and verified as ha%ing an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals). As required by <br /> the Building Official,testing shall be conducted by an approved third party.A written repon of results of the test <br /> shall be signed by the party conducting the test(including Agency Name)and provided to the Budding Official prior to <br /> Certificate of Occupancy issuance.Testing shall be performed at any time after creation ofall scheduled penetrations of <br /> the building thermal envelope. <br /> During testing.(check to verify condition met) <br /> Ve <br /> Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,bey W the intended weather- <br /> ,,, Exterior <br /> or other <br /> Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not sealed beyond <br /> Vntended infiltration <br /> /i' <br /> Me, <br /> V-1 i tenor doors,if installed at the time of the test,shall be open <br /> n <br /> Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed <br /> sting and coding systems,if installed at the time of the test,shall be turned off <br /> Su <br /> S upply and return registers,if installed at the time of the test,shall be fully open <br /> Vb Building volume(ft ) Vz�3 LID <br /> Q5o Airflow at 50 Pascal(CFM) <br /> ACH5o Air changes per hour at 50 Pascal <br /> Qso x 60 Vb — — , i 0� ACH:5o (3.0ACHminimum) <br /> Pass VW", Fail F <br /> Outside Air mechanically introduced to space(less than 3.0 ACH) <br /> I hereby certify that the above envelope leakage performance results demonstrate compliance <br /> with Florida Energy Code requirements in accordance with Section R402.4 1.2. <br /> Signature of Tester Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.