My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20405
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20405
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:23:10 AM
Creation date
6/4/2019 7:23:09 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20405
Building Department - Name
LENNAR HOMES LLC
Address
39615 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ucy r I (P -ft-;.o 4oS <br /> Jet Stream° Ultra Mowing Wool Insulation <br /> Attic and Cavity Wall Card �3 6� 6 '5 D&WsoYI Glee_ ih lime h mve &1erg <br /> Batts and Blankets Equipment Required <br /> When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum''/4"internal corrugation,a minimum length <br /> recommendations,Knauf Insulation baits and blankets will of 150'.Coils in the hose should not be less than 36'in diameter.Acceptable material feed rate is 5-35 lbs/minute.Recommended feed <br /> provide the full R-value. rate is 15.25 lbs/minute. <br /> R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) <br /> To obtain The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the <br /> insulation resistance <br /> Installed insulation should ance required Dumber of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label <br /> (R-Value)of: not be less than: will result in lower installed R-values,Field blending of this product with other loose fill insulations Is not recommended by the manufacturer. <br /> R49 13.75" Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. <br /> R-38HD 10.25" <br /> R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum <br /> R-30HD 8.25" To obtain an The number of bags Coverage per Bag Weight per SF <br /> Insulation per 1,000 square feet Contents of this The weight per square <br /> R-30 10,00" Cavity resistance of not area should not bag should not feet of installed Insulation <br /> R-26 g 00" Framing Depth of: Density be less than: cover more than: should not be less than: <br /> R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs. <br /> R-21 HD 6.50" 2°x 6" 5.50" R-23 1.8 Ibs.1cu.ft. 25.8 bags 38.8 sq.ft 0.825 tbs, <br /> R-19 6.25' 2"x 8" 7.25" R-31 1.8 lbs./cu.ft. 34.0 bags 294 sq.ft. 1.088 lbs. <br /> R-15HD 3.50" <br /> R-13 3.50" 2"x 10" 9.25" R-39 1.8 lbs./ou.ft. 43.4 bags 23.1 sq.ft. 1.388 tbs. <br /> R-11 3.50" R means resistance to heat Sow.The higher the R-value,the greater the Insulating power.To gel the marked R-value,it is essential that this insulation be installed property. <br /> R-8 2.50" <br /> "R-18Ina5.5"cavity.Conforms toASTMC665andFede.1 Open Attic Application Bag Net Weight-Nominal 32 tbs.,Minimum 31 tbs. <br /> Specification HH-1-521F. Minimum <br /> Bags/ Maximum Minimum Initial Settled <br /> Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** <br /> To compensate for framing members,the number of bags per The number of bags/ Contents of this The weight/SF Thickness Contents of this <br /> 1,000 sq.ft.of area to be insulated should be as shown below. R-Value* 1,000 SF of not area bag should not of Installed Installed insulation bag should <br /> Ba slMSF Ba sIMSF To obtain an insulation should not be less cover insulation should not should not be less not cover more <br /> 9 g resistance(R-Value)of: than: more than: be <br /> Framing <br /> Framing <br /> R-Value Dimensions Framing fra ming less than than: than: <br /> Joist O.C. O.C. R-60 29.7 33.6 SF .952 lbs. 19,750" 19.750" <br /> 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 tbs. 16,375" 16.375" <br /> R-60 2x6 28.9 29.1 R-44 20,9 47.8 SF .670lbs. 14.875" %875" <br /> 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 tbs. 13,000, 13,000, <br /> 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375" <br /> R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 tbs. 9.125" 9.125" <br /> 2x8 22.4 22.7 R-22 9.8 102.2 SF .313 lbs. 7.750" 7.750" <br /> 2x4 20.4 20.6 <br /> R-44 26 20.1 20.3 R-19 8.4 119.3 SF .268 tbs. 6.750" 1 6.750" <br /> 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4,750" 4,750" <br /> 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 tbs. 4.000" 4.000" <br /> R-38 2x6 17.0 17.2 Bag Net Weight-Nominal 321bs.,MNmum 31 tbs. <br /> 2x8 16.7 17.0 Coverage and ustagation Bala were determined using a VolmMatle If blowmg machine In third gear win 13'gate opening,2.0 psi air pressure and 150'of V inlemagy<anugated hose. <br /> This product conforms to the performance requirements ofASTM C 764,Type 1,and cancelled Federal Spedtika0ae MH4-10308,Type i,Class&R-values am determined in aeccordarrce wtih C 697 and C S13. <br /> 2x4 13.2 13.3 -'W means resistance to heat fim The hoar the RwAe,the greater the vtsulaimg pow..To get ftmarked R-value.it is essential thatch's insulatkIn be inshged property gym doit yourself,get instmc- <br /> R-30 2x6 12.9 13.1 Lions and follow them carefully Instructions do not come Wlh this package. <br /> "Based on Third Party 2-year senrmg study,the predicted settlement over a 20year period would be 1 percent or less.This amount of settling Is thermally insignificant.Therefore,the mstalted and settled <br /> 2x8 12.6 12.9 thidmeses are effectively the some. <br /> 2x4 11.3 11.4 "ats'llIsaregstereduademakofurdwi <br /> R-26 2x6 11.0 11,2 Builder's Insulation Statement <br /> 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... <br /> 2x4 9.3 9.5 R-Value Thickness <br /> R-22 2x6 9.1 9.3 Attic Area R- at Inches - <br /> 2x8 8.8 9.1 Sloped Ceilings R- at Inches <br /> 2x4 7.9 8.1 Walls R- at Inches <br /> R-19 2x6 7.7 7.9 Floors(over an unheated crawl space) R- at Inches <br /> 2x8 7.4 7.7 <br /> 2x4 5.3 5.4 Crawl Space Perimeter R- at Inches <br /> R-13 26 5.0 5.2 Date Installed <br /> 2x8 4.8 5.0 Blown 1 ulation has been i t led in conformance with the above race n tions4provide an R-value of: <br /> "2x4 4.3 4.4 R- J-Q using � bags of this insulation to cover square feet of area <br /> 4.1 4.3 at a minimum thickness of inches. <br /> 3.8 4.1 <br /> Imi'm Nipi�(cin��6ira At <br />
The URL can be used to link to this page
Your browser does not support the video tag.