Jet Stream° Ultra Blowing Wool Insulation kiufpW <br /> Attic and Cavity Wall Card D� Mo u I Jem �6 16i ih lime h jave, e4ierf <br /> Batts and Blankets Equipment Required <br /> When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum'/4'internal corrugation,a minimum length <br /> recommendations,Knauf Insulation batts and blankets will of 150'.Coils in the hose should not be less than 36'in diameter.Acceptable material feed rate is 5-35 lbs/minute.Recommended feed <br /> provide the full R-value. rate is 15-25 lbs/minute. <br /> R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) <br /> To obtain an The stated thermal resistance(R-value)Is provided by installing in accordance with the manufacturer's instructions.Failure to install the <br /> insulation resistanca Installed insulation should required number of bags per 1,000 square feet and exceeding Me maximum square feet of coverage per bag as recommended by the label <br /> (R-Value)of: not be less than: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. <br /> R-49 13.75' Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. <br /> R-38HD 10.25" <br /> R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum <br /> R-30HD 8.25" To obtain an The number of bags Coverage per Bag Weight per SF <br /> insulation per 1,000 square feet Contents of this The weight per square <br /> R-30 10.00" Cavity resistance of net area should not hag should not feet of Installed insulation <br /> R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: <br /> R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs. <br /> R-21HD 5.50" 2"x 6" 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs. <br /> R-19 6.25"** <br /> R-15HD 3.50" 2"x 8" 7.25" R 31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 Ibs, <br /> R-13 3.50" 2"x 10" 9.25° 1 R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs. <br /> R-11 3.50" R means resistance to heat flow.The higher the R-value,the greater the insulating power.To get the marked R-value,it is essential that this insulation be Installed property. <br /> R-8 2.50" <br /> "R48 in a 5.5'cavity.Conforms toA8TMC665 and Federal Open Attic Application Bag Net Weight-Nominal 32lbs.,Minimum 31 lbs. <br /> Specificaflon HH-1.521F. Minimum <br /> Bags/ Maximum Minimum Initial Settled <br /> Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** <br /> To compensate for framing members,the number of bags per The number of bags/ Contents of this The wef ht(SF Thickness <br /> 1,000 s ft.of area to be insulated should be as shown below. R-Value* g Contents of this <br /> q• 1,000 SF of net area hag should not of installed Installed insulation hag should <br /> Ba s/MSF Ba S/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more <br /> g 9 resistance(R-Value)of: than: more than: he less than than: than: <br /> Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF 952 lbs. 19.750" 19.750" <br /> R-Value Dimensions Framing Framing <br /> 2x4 29.2 29.4 R49 23.5 42.5 SF .753 lbs. 16.375' 16.375" <br /> R-60 2x6 28.9 29.1 R44 20.9 47.8 SF .670lbs. 14.875" 14.875" <br /> 2x8 1 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000" <br /> 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375" <br /> R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125" 9.125" <br /> 2x8 22.4 22.7 R-22 9.8 102.2 SF 313 lbs. 7.750" 7.750" <br /> 2x4 20.4 20.6 <br /> R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750" 6.750" <br /> 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750" 4.750" <br /> 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000° 4.000" <br /> R-38 2x6 17.0 17.2 Bag Net Weight-Nominal32 lbs.,Knimum31Its. <br /> 2x8 16.7 17.0 Coverage and installation data were determined using a Votu4Aal1&II bowing machine in third Bearwn Is'gate opening,2.0 psi air pressure and 150'of W intemaly-comgated hose. <br /> 2x4 13,2 13.3 This product conforms to the performance requirements ofASTM C 764,Type I,and cancelled Federal Specification HH-I.1030B,Type I,Class B.R-values are determined In accordance with C 687 and C 618. <br /> "R'means resistance to heat Dow.The higher the R-value,the greater the insulating power.To gel the marked R-value,It is essential that this Insulation be Installed properly.If you do it yourself,gel inmuo- <br /> R-30 2x6 12.9 13.1 Dons and follow them carefully.Instructions do not come with this package. <br /> "Based on Third Party 2-year settling study,the predicted settlement over a 20-year period wauld be 1 percent or less.This amount of setting is thermally Insignificant.Therefore,the installed and settled <br /> 2x8 12.6 12.9 tNdmesses are effectively the same. <br /> 2X4 11.3 11.4 Volu-MaDdll Is a registered trademark at Unisul. <br /> R-26 2x6 11.0 11.2 Builder's Insulation Statement <br /> 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... <br /> 2x4 9.3 9.5 R-Value Thickness <br /> R-22 2x6 9.1 9.3 Attic Area R- at Inches <br /> 2x8 8.8 9.1 Sloped Ceilings R- at Inches <br /> 2x4 7.9 8.1 Walls R- at Inches <br /> R-19 2x6 7.7 7.9 Floors(over an unheated crawls ace) R- at Inches <br /> 2x8 7.4 7.7 <br /> 2x4 5.3 5.4 Crawl Space Perimeter R- at Inches <br /> R-13 2x6 5.0 5.2 Date Installed <br /> 2x8 4.8 5.0 Blow s lation has been' t led in conformance with the above reco�n��do to provide an R-value of: <br /> 2x4 4.3 4.4 R�_using bags of this insulation to cover�-- square feet of area <br /> R-11 2x6 4.1 4.3 at a minimum thickness of inches. <br /> 2x8 3.8 4.1 <br />