My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20426
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20426
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 9:59:40 AM
Creation date
6/4/2019 7:29:27 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20426
Building Department - Name
LENNAR HOMES LLC
Address
35994 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Project Summary Job: 2277E sf ADS Carrier <br /> J •y Date: 8/13/2018 <br /> Entire House By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Notes: FBC 2017 <br /> Design In • • <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 39 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 26341 Btuh Structure 24133 Btuh <br /> Ducts 3495 Btuh Ducts 3421 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 29836 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 27555 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2506 Btuh <br /> Ducts 730 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 2278 2278 Equipment latent load 3236 Btuh <br /> Volume(ft3) 19162 19162 <br /> Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 30791 Btuh <br /> Equiv.AVF(cfm) 70 35 Req. total capacity at 0.85 SHR 2.7 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC536AO0300 Cond 25HBC536AO0300 <br /> AHRI ref 9155179 Coil FX4DNF037L <br /> AHRI ref 9155179 <br /> Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER <br /> Heating input Sensible cooling 29580 Btuh <br /> Heating output 34600 Btuh @ 47°F Latent cooling 5220 Btuh <br /> Temperature rise 26 OF Total cooling 34800 Btuh <br /> Actual air flow 1200 cfm Actual air flow 1200 cfm <br /> Air flow factor 0.040 cfm/Btuh Air flow factor 0.044 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.89 <br /> Capacity balance point=28 OF <br /> Backup: n/a n/a <br /> Input= 0 kW, Output = 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wrightsoft� 2018-Aug-1 3 15:12:07 <br /> ^�^ w, .•�_a Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> A'O ...77 sf ADS Tampa ONLY template 3 ton Carrier.rup Calc=MJ8 Front Door faces:NE <br />