Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20426
Building Department - Name
LENNAR HOMES LLC
Address
35994 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 2277B sf ADS CarrierDate: 811 312 01 8 <br /> Entire House By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 27555 Btuh Entering coil DB: 75.5°F <br /> Outdoor design WB: 77.3°F Latent gain: 3236 Btuh Entering coil WB: 62.8°F <br /> Indoor.design DB: 75.0°F Total gain: 30791 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29580 Btuh 107% of load <br /> Latent capacity: 5220 Btuh 161% of load <br /> Total capacity: 34800 Btuh 113% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 29836 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Output capacity: 26344 Btuh 88% of load Capacity balance: 28 OF <br /> Supplemental heat required: 3492 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 OF <br /> Meets all requirements ofACCA Manual S. <br /> L Wrightsoft- 2018-Aug-1315:12:07 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ACCK ...77 sf ADS Tampa ONLY template 3 ton Carrier.rup Calc=MJ8 Front Door faces:NE <br />
The URL can be used to link to this page
Your browser does not support the video tag.