Project Summary, Job: 2485A sf ADS Carrier <br /> J Summary Date: 8/14/2018 <br /> Entire House By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Notes: FBC 2017 <br /> ---Desicin Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 32 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 38 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 28907 Btuh Structure 24099 Btuh <br /> Ducts 3517 Btuh Ducts 3519 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> none <br /> Humidification 0 Btuh Blower e) 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 32424 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 27618 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2537 Btuh <br /> Ducts 730 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 2443 2443 Equipment latent load 3267 Btuh <br /> Volume(ft3) 22893 22893 <br /> Air changes/hour 0." 0.11 Equipment Total Load (Sen+Lat) 30885 Btuh <br /> Equiv.AVF (cfm) - 84 42 Req. total capacity at 0.85 SHR 2.7 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model 25HBC536AO0300 Cond 25HBC536AO0300 <br /> AHRI ref 9155179 Coil FX4DNF037L <br /> AHRI ref 9155179 <br /> Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER <br /> Heating input Sensible cooling 29580 Btuh <br /> Heating output 34600 Btuh @ 470F Latent cooling 5220 Btuh <br /> Temperature rise 26 OF Total cooling 34800 Btuh <br /> Actual air flow 1200 cfm Actual air flow 1200 cfm <br /> Air flow factor 0.037 cfm/Btuh Air flow factor 0.043 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.89 <br /> Capacity balance point= 32 OF <br /> Backup: n/a n/a <br /> Input= 0 kW, Output= 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -Pl&- =ightsott- 2018-Aug-14 09:55:14 <br /> ��- ^��•� w--ry�mpw Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ACCA ...equipment\2485 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces:SW <br />