Laserfiche WebLink
Manual S Compliance Report Job: 2485A sf ADS Carrier <br /> Date: 8/1 412 01 8 <br /> Entire House By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 27618 Btuh Entering coil DB: 75.5°F <br /> Outdoor design WB: 77.2°F Latent gain: 3267 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 30885 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29580 Btuh 107% of load <br /> Latent capacity: 5220 Btuh 160% of load <br /> Total capacity: 34800 Btuh 113% of load SHR: 85% <br /> -Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 32.1°F Heat loss: 32424 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Output capacity: 27079 Btuh 84% of load Capacity balance: 32 °F <br /> Supplemental heat required: 5345 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets all requirements of ACCA Manual S. <br /> Ai -Fo wrightsoft® 2018-Aug-14 09:55:14 <br /> , .rR.���.w,�.,� Right-Suite®Universal 2018 18.0.16 RSU05714 <br /> �� Page 1 <br /> ...equipment\2485 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces:SW <br />