Buildin Anal SI$ Job: 3246A sf ADS Carrier <br /> g Y Date: 7125/2018 <br /> upper floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Design C• • • <br /> Location: Indoor: Heating Cooling <br /> Sarasota Bradenton, FL, US Indoor temperature ff) 70 75 <br /> Elevation: 26 ft Design TD (°F) 38 17 <br /> Latitude: 27°N Relative humidity(%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0 <br /> Dry bulb(°F) 33 92 Infiltration: <br /> Daily range(°F) - 14 ( L ) Method Simplified <br /> Wet bulb(°F) - 79 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> • <br /> Component Btuh/ftz Btuh % of load <br /> Walls 3.6 4072 30.3 ucts <br /> Glazing 28.9 3827 28.5 wall <br /> Doors 0 0 0 <br /> Ceilings 1.2 1650 12.3 nfiltration <br /> Floors 1.9 9 0.1 <br /> Infiltration 1.7 2161 16.1 <br /> Ducts 1727 12.8 other <br /> Piping 0 0 Ceilings <br /> Humidification 0 0 <br /> Ventilation 0 0 Glazing <br /> Adjustments 0 <br /> Total 13445 100.0 <br /> • • i <br /> Component Btuh/ft2 Btuh % of load <br /> Walls 2.8 3171 18.1 <br /> Glazing 50.7 6724 38.4 walls Internal Gains <br /> Doors 0 0 0 <br /> Ceilings 1.8 2424 13.8 <br /> Floors 0.9 4 0.0 Ducts <br /> Infiltration 0.4 518 3.0 <br /> Ducts 1814 10.4 <br /> Ventilation 0 0 Infiltration <br /> Internal gains 2855 16.3 other <br /> Blower 0 0 <br /> Adjustments 0 Glazing Ceilings <br /> Total 17510 100.0 <br /> Latent Cooling Load= 3279 Btuh <br /> Overall U-value= 0.097 Btuh/ftz-°F <br /> Data entries checked. <br /> =1Qhtsc ft- 2018-Jul-25 13:58:14 <br /> MCA ^�°° �°°w yam. Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N <br />