Summary Project •' Job: 3246A sf ADS Carrier <br /> Date: 7/2512018 <br /> lower floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> i <br /> For: Lennar Homes <br /> Notes: <br /> Design Information <br /> Weather: Sarasota Bradenton, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 33 OF Outside db 92 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 38 OF Design TD 17 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 63 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 21659 Btuh Structure 17912 Btuh <br /> Ducts 2010 Btuh Ducts 2101 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 23670 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 20013 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 1381 Btuh <br /> Ducts 478 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz) 1880 1880 Equipment latent load 1859 Btuh <br /> Volume(ft') 16486 16486 <br /> Air changes/hour 0.23 0.12 Equipment Total Load (Sen+Lat) 21871 Btuh <br /> Equiv.AVF(cfm) 62 32 Req. total capacity at 0.85 SHR 2.0 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9154943 Coil FB4CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER. j <br /> Heating input Sensible cooling 20400 Btuh <br /> Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.034 cfm/Btuh Air flow factor 0.040 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.92 <br /> Capacity balance point= 33 OF <br /> Backup: <br /> Input= 7 kW, Output=24093 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> .� -Fk wrightsoft- 2018-Jul-25 13:58:14 <br /> ^�^•�a• a•^- - Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N <br />