Laserfiche WebLink
Enve ope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERi Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: Permit#: <br /> Job tnfortnatton <br /> ;7u F <br /> Builder: DRH Express Homes Community: Lot: . 2/11 <br /> Address: <br /> City: Zephyrhills State: FL Zip: <br /> t 1.E kad4 ,TeSIC R�sulftS , Passing resuJts'rrrust meet either the Fedor' ce,:', Tescriotrve or Rt Method'. <br /> F!RBSCft(Pl iUE METH{?L1 The building or dvieIIln ,bhft shall b6 tested'and verified as haying an air ieakagp rate ofxnot exceeding 7 air <br /> changes per hour at a pressure of 0,2 inch uy g:(50 Pascals)in.Climate Zones 1 and 2 <br /> . t <br /> PEt3FORiUlAt3fCE or ERI{METHAD the building or dwelling unit shall be,tesled arid'verified as having an air leakage fate ofi not exceeding <br /> ;the selected ACH(%)Yalue as shpwn an dorm Fi405 2p17(Performance),or R406 2017.(ERI),section labeled as:infiltratiop,subsection ACH56. <br /> ACFf(�0)specified on`Form r?4C15 2017 4Energy Gaio(P rfomaanceJ or R406 20 t 7(ERJ), : 7.000 <br /> x 60 _ 14496 = Method for calculating buildingv olume: <br /> CFM(50) Building Volume ACH(50) Q Retrieved from architectural plans <br /> ❑ PASS 0 Code software calculated <br /> When ACH(50)is less than 3, Mechanical Ventilation installation- 0 Field measured and calculated <br /> must be verified by building department. - <br /> R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) <br /> Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section <br /> 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and <br /> provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended we-atherstripping or other infiltration <br /> control measures'. <br /> 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control <br /> measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. <br /> 6.Supply and return registers,if installed at the time of the test,shall.be fully open. <br /> ;Testing`Company <br /> Company(Name: Phone:- <br /> I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code <br /> Energy Conservation requirements according to the compliance method selected above. - <br /> Signature of Tester: Date of Test: <br /> Printed Name of Tester: <br /> License/Certification#: Issuing Authority: <br /> 8/31/201 8 1 0:32:46 AM Energypauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2617)Compliant Software. Page 1 of 1 <br />