My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20446
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20446
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:36:34 AM
Creation date
6/4/2019 7:36:32 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20446
Building Department - Name
DR HORTON INC
Address
6788 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I + <br /> j <br /> Duct Leakage Test Report <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: Permit#: <br /> Job Informatiari . <br /> Builder: DRH Express Homes Community: - Lot: 4/11 <br /> Address: <br /> City: Zephyrhills State: FL Zip: <br /> ;Duct Leakage,Test Resuit.s (� Prescriptive Method 0 , Performance/ERI Method <br /> System 1 cfm25 Prescriptive Method .6625(Total) <br /> System 2 cfm25 To qualify±as"substantially leak.free"'Qn Total must.be:.less than or <br /> equal to 0,04,if.air handler unttis installed, if air,handler.unit is not <br /> System 3 cfm25 installed,On Total must be less than or equal to 0.03.Thistestind <br /> method meets the requirements in accordance With Section R443.3.3:. <br /> Sum of any cfm25 is the air-handier unit installed during testing? 'YES ONO{1.60") <br /> Total of all cfm25 <br /> 0 Performance%ERI Method ,cfm25(,out or Total); <br /> To.qualify Using,this method,Qn,-mutt not be dreater than the <br /> 1751 = On 'proposed duct leakage On specified oh'Folrm,R405-2017 or R406.-2017 <br /> Total of all Total Conditioned <br /> systems square Footage Leakage Type selected,on Form Qn specified on Form R405-2047 <br /> R405-2017(EnergyCalc)or R406-2017 (Energycalc)orrR406'-20i7 <br /> PASS FAIL Proposed Qn 0.05 <br /> Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section <br /> 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f), (g)or(i), Florida Statutes. <br /> Testing.Compy <br /> an :', <br /> Company Name: Phone: <br /> I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the <br /> selected compliance path as stated above,either the Prescriptive Method or Performance Method. <br /> Signature of Tester: Date of Test: <br /> Printed Name of Tester: <br /> License/Certification#: Issuing Authority: <br /> 8/31/2018 11:42:57 AM EnergyGaugeD USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.