My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20446
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20446
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:36:34 AM
Creation date
6/4/2019 7:36:32 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20446
Building Department - Name
DR HORTON INC
Address
6788 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> -�- wrightsof�� <br /> Manua! S Compliance Report Job:: <br /> Entire Douse By: <br /> Progressive Air ',.i' (stems, Inc Plan: Neuville 1751 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> • 4 0 b <br /> For: DR Horton <br /> Lot 4 Blk 11 Silverado, Zephyrhills, FL <br /> 4 b • S @ <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 21246 Btuh Entering coil DB: 76.1OF <br /> Outdoor design WB: 77.1 OF Latent gain: 2957 Btuh Entering coil WB: 63.0°F <br /> Indoor design DB: 75.0°F Total gain: 24203 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASH <br /> Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23399 Btuh 110%of load <br /> Latent capacity: 3923 Btuh 133%of load <br /> Total capacity: 27322 Btuh 113%of load SHR: 86% <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 20877 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25626 Btuh 123%of load Capacity balance: . 31 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm <br /> Output capacity: 5.8 kW 95% of load Temp. rise: 50 OF <br /> Meets are all requirements of ACCA Manual S. <br /> i liBoPr 2018-Aug-31 11:46:20 <br /> y^'' Right-SuiteB Universal 2017't7.0.21 RSU25554 - Page 1 <br /> 'CA ...rightsolt Files\Express homes\Neuvilie 1751.rup Calc-MJ8 House Front faces:NW <br />
The URL can be used to link to this page
Your browser does not support the video tag.