My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19892
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19892
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 8:15:04 AM
Creation date
9/18/2019 9:13:29 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA MEDICAL CLINIC
Building Department - Doc Type
Permit
Permit #
18-19892
Building Department - Name
FLORIDA MEDICAL CLINIC
Address
36763 EILAND BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
131
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Review C103.2 Mechanical Plans,specifications,and/or calculations provide <br /> all information with which compliance can be <br /> determined for the mechanical systems and <br /> equipment and document where exceptions to the <br /> standard are claimed. Load calculations per <br /> acceptable engineering st �❑ <br /> Plan Review 0103.2 Mechanical Plans,specifications,and/or calculations provide <br /> all information with.which compliance can be <br /> determined for the service water heating systems <br /> and equipment and document where exceptions <br /> to the standard are claimed. Hot water system <br /> sized per manufact <br /> Plan Review C103.2 Interior Lighting Plans,specifications,and/or calculations provide <br /> all information with which compliance can be <br /> E determined for the interior lighting and electrical <br /> if systems and equipment and document where <br /> exceptions to the standard are claimed. <br /> Information provided shoul <br /> Plan Review C103.2 Exterior Lighting Plans,specifications,and/or calculations provide <br /> 1 all information with which compliance can be <br /> determined for the exterior lighting and electrical <br /> systems and equipment and document where <br /> exceptions to the standard are claimed. <br /> iiii Information provided shoul <br /> Insulation C402.2.5 Envelope Slab edge insulation depth/length.Slab insulation <br /> extending away from building is covered by <br /> pavement or>=10 inches of soil. <br /> Insulation C4o2.2.6. Project Radiant heating systems panels insulated to <br /> >=R-3.5 on face opposite space being heated. <br /> HVAC C402.2.6 Mechanical Thermally ineffective panel surfaces of sensible <br /> heating panels have insulation>=R-3.5. <br /> Insulation C402.2.6 Envelope Radiant panels and associated components, <br /> i designed for heat transfer from the panel surfaces <br /> to the occupants or indoor space are insulated <br /> with a minimum of R-3.5. <br /> Air Leakage C402.5.7 Envelope Vestibules are installed on all building entrances. <br /> Doors have self-closing devices. <br /> SYSTEM—SPECIFIC C403.2.12.3 Mechanical Fans have efficiency grade (FEG)>=67.The total <br /> efficiency of the fan at the design point of <br /> operation—15%of maximum total efficiency of <br /> the fan. ® —/ <br /> HVAC C403.2.13 Mechanical Unenclosed spaces that are heated use only <br /> radiant heat. <br /> HVAC C403.2.4.2 Mechanical Each zone equipped with setback controls using <br /> automatic time clock or programmable control <br /> system. <br /> SYSTEM—SPECIFIC C403:2.4.4 Mechanical Zone isolation devices and controls installed <br /> where applicable. <br /> SYSTEM_SPECIFIC C403.2.4.7 Mechanical Fault detection and diagnostics installed with. ® 2( 13 <br /> air-cooled unitary DX units having economizers. <br /> SYSTEM—SPECIFIC C403.2.5 Mechanical Hot water boilers supplying heat via one-or <br /> two-pipe systems include outdoor setback control. <br /> HVAC C403.2.6.1 Mechanical Demand control ventilation provided forspaces 0 El <br /> >500 ft2 and>25 people/1000 ft2 occupant <br /> density and served by systems with air side <br /> economizer,auto modulating outside air damper <br /> control,or design airflow>3,000 cfm. <br /> SYSTEM—SPECIFIC C403A.1.1 Mechanical Hydronic and multizone HVAC system controls v( 0 0 <br /> I areVAV fans driven by mechanical or electrical <br /> — variable speed drive per Table C403.4.1.1. <br /> SYSTEM SPECIFIC C403.4.1.3 Mechanical Reset static pressure setpoint for DDC controlled <br /> VAV boxes reporting to central controller based on <br /> the zones requiring the most pressure. <br /> SYSTEM.SPECIFIC C403.4.2 Mechanical Temperature,reset by representative building <br /> loads in pumping systems for chiller and boiler <br /> systems>500,000 Btu/h. <br /> I <br /> i EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 <br /> Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option <br /> 2/13/2018 Page 11 of 25 <br />