SYSTEM—SPECIFIC C403.4.2"3.2.1 Mechanical Closed-circuit cooling tower within heat pump loop, <br /> have either automatic bypass valve or lower <br /> leakage positive closure dampers.Open-circuit <br /> tower within heat pump loop have automatic valve <br /> to bypass all heat pump water flow around the <br /> tower.Open-or cl ❑ ❑ <br /> SYSTEM—SPECIFIC C403.4.2.4 Mechanical Hydronic systems greater than 500,000 Btu/h <br /> designed for variable fluid flow. <br /> SYSTEM-SPECIFIC C403.4.2.5 Mechanical System turndown requirement met through ❑ 2(El <br /> multiple single-input boilers,one.or more <br /> modulating boilers,or a combination of <br /> single-input and modulating boilers. <br /> Boiler input between 1.0 MBtu/h and 5 MBtulh <br /> has 3:1 turndown ratio,boiler Input between 5.0 ❑ ❑ <br /> SYSTEM—SPECIFIC C403.4.2.6 Mechanical Chilled water plants,with multiple chillers have <br /> capability to reduce flow auto matically'through the <br /> chiller plant when a chiller is shut down. <br /> Boiler plants with multiple boilers have the <br /> capability to reduce flow automatically through the <br /> boiler plant <br /> SYSTEM—SPECIFIC C403.4.3, Mechanical Fan systems with motors>=7.5 hp associated <br /> C403.4.3.2 with heat rejection equipment to have capability to <br /> operate at 213 of full-speed and auto speed <br /> controls to control the leaving fluid temperature or <br /> condensing temp/pressure of heat rejection <br /> device. i/❑ ❑ <br /> SYSTEM—SPECIFIC C403.4.4.5 Mechanical Multiple zone HVAC systems have supply air <br /> temperature reset controls. <br /> SYSTEM—SPECIFIC C403.4.4.6 Mechanical Multiple zone VAV systems with DDC of individual <br /> zone boxes have static pressure setpoint reset <br /> controls. <br /> SYSTEM—SPECIFIC C404.2.1 Mechanical Gas-fired water-heating equipment installed in <br /> new buildings:where a singular piece of <br /> water-heating equipment=1,000 kBtu/h serves <br /> the entire building,thermal efficiency—90 Et. <br /> Where multiple pieces of water-heating <br /> equipment serve the building wi <br /> SYSTEM—SPECIFIC C404.4 Mechanical All piping insulated in accordance with section <br /> details and Table C403.2.10. <br /> SYSTEM_SPECiFIC C404.5,C404.5.1, Mechanical Heated water supply piping conforms to pipe <br /> C404.5.2 length and volume requirements:Refer to section <br /> details. Or <br /> SYSTEM SPECIFIC C404.6.3 Mechanical Pumps that circulate water between a heater and <br /> storage tank have controls that limit operation <br /> from startup to—5 minutes after end of heating <br /> cycle. ❑ <br /> SYSTEM—SPECIFIC C404.7 Mechanical Water distribution system that pumps water from <br /> 11, <br /> a heated-water supply pipe back to the <br /> heated-water source through a cold-water supply <br /> pipe is <br /> a demand recirculation water system.Pumps <br /> within this system have controls that start the <br /> pump upon receiving ❑ <br /> Wattage C405.5.1 Exterior Lighting Exterior lighting power is consistent with what is <br /> shown on the approved lighting plarfs, <br /> demonstrating proposed watts are less than or <br /> equal to allowed watts. <br /> Plan Review C405.6 Project Group R-2 dwelling units have separate electrical <br /> meters. <br /> Plan Review C406 Project Plans,specifications,and/or calculations provide 12(13 <br /> all information with which compliance can be <br /> determined for the additional energy efficiency <br /> package options. <br /> SYSTEM—SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have <br /> means to balance and have pressure test <br /> connections. <br /> SYSTEM—SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have V(El <br /> means to balance and have pressure test <br /> connections. <br /> EnergyGauge Summit@)Fla/Com-2017.TAM 2017-1.0 Compliant Software"Effective Date:Dec 31,2017 <br /> Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option <br /> 2/13/2018 Page 12 of 25 <br />