My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20002
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2019 9:43:14 AM
Creation date
9/18/2019 9:43:13 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM
Building Department - Doc Type
Permit
Permit #
18-20002
Building Department - Name
ADVENTIST HEALTH SYSTEM
Address
7350 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ZEPHYRHILLS <br /> FIftAND LIFE$AFETY EXAMINE w . <br /> Worldwide www.tyco-fire.com <br /> Fire Protection ALL WORK SHALL COMPLY WITH Contacts <br /> Products NFFA CODES AND STANDARDS <br /> Series TY-FRB, 5.6 K-factor <br /> Upright, Pendent, and Recessed Pendent Sprinklers <br /> Quick Response, Standard Coverage <br /> General CEM <br /> The TYCO Series TY-FRB Sprinklers .°. <br /> Description described herein must be installed -` <br /> p and maintained in compliance with <br /> The TYCO Series TY-FRB,5.6 K-factor, this document, as well as with the ;'"=°'-:-�. <br /> Upright (TY313) and Pendent (TY323) applicable standards of the National � <br /> Sprinklers described in this data sheet Fire Protection Association,in addition <br /> are quick response,standard coverage, to the standards of any other authori- <br /> decorative 3 mm glass bulb-type spray ties having jurisdiction.Failure to do so <br /> sprinklers designed for use in light or may impair the performance of these <br /> ordinary hazard,commercial occupan- devices. <br /> cies such as banks, hotels, and shop- <br /> The owner is responsible for main- <br /> ping malls. taining their fire protection system <br /> The recessed version of the Series and devices in proper operating con- <br /> TY-FRB Pendent Sprinkler, where dition. Contact the installing contrac- <br /> applicable,is intended for use in areas for or product manufacturer with any \ <br /> with a finished ceiling. This recessed questions. im �I I <br /> pendent sprinkler uses one of the <br /> following: Sprinkler <br /> • A two-piece Style 15 Recessed <br /> Escutcheon with recessed adjust- Identification _. f <br /> ment up to p �l/111ber ®�® <br /> o 5/8 inch(15,9 mm)from <br /> the flush pendent position. ( ) r <br /> • A two-piece Style 20 Recessed TY313 . .. . . Upright 5.6K, 1/2" NPT <br /> :,::-�-;,��•�;, <br /> Escutcheon with recessed adjust- TY323 . .. . .Pendent 5.6K,1/2-NPT <br /> ment up to 1/2 inch (12,7 mm)from <br /> the flush pendent position. Technical <br /> The adjustment provided by the operation <br /> Recessed Escutcheon reduces the Data <br /> accuracy to which the fixed pipe drops The glass bulb contains a fluid which <br /> to the sprinklers must be cut. Approvals expands when exposed to heat.When <br /> Intermediate level versions of Series Refer to Table A the rated temperature is reached, the <br /> TY-FRB Sprinklers are described in Maximum Working Pressure fluid expands sufficiently to shatter the <br /> Technical Data Sheet TFP357. Sprin- 175 psi(12.1 bar) glass bulb, allowing the sprinkler to <br /> kler guards and shields are described 250 psi(17.2 bar)` activate and water to flow. <br /> in Technical Data Sheet TFP780. •The maximum working pressure of 250 psi(17.2 bar) Design <br /> only applies to the listing by Underwriters Laborato- <br /> ries,Inc.(UL). <br /> Discharge Coefficient Criteria <br /> K=5.6 GPM/psi'/2(80,6 LPM/bar'/2) The TYCO Series TY FRB,5.6 K-factor, <br /> Temperature Rating Upright (TY313) and Pendent (TY323) <br /> Refer to Table A Sprinklers are intended for fire protec- <br /> IMPORTANT Finishes tion systems designed in accordance <br /> Always refer to Technical Data Sprinkler:Refer to Table B with the standard installation rules <br /> Sheet TFP700 for the "INSTALLER recognized by the applicable Listing or <br /> Recessed Escutcheon:White Coated, Approval agency (such as, UL Listing <br /> WARNING"that provides cautions Black Coated,Chrome Plated,or Brass is based on the requirements of NFPA <br /> with respect to handling and instal- Plated 13, and FM Approval is based on the <br /> lation of sprinkler systems and com- <br /> ponents. Improper handling and Physical Characteristics requirements of FM's Loss Prevention <br /> installation can permanently damage Frame ............................Bronze Data Sheets).Only the Style 15 or Style <br /> a sprinkler system or its compo- Button......................Brass/Copper 20 Recessed Escutcheon is to be used <br /> vents and cause the sprinkler to fail Sealing Assembly...Stainless Steel w/TEFLON for recessed pendent installations. <br /> too operate in a fire situation or cause Bulb Compression <br /> Screw <br /> ...................Glass <br /> P Compression Screw.................Bronze <br /> it to operate prematurely. Deflector..........................Bronze <br /> Page 1 of 4 JULY 2017 TFP172 <br />
The URL can be used to link to this page
Your browser does not support the video tag.