Laserfiche WebLink
TFP17,2 <br /> Page 2of4 <br /> Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 <br /> 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. <br /> 2 - Button 5 - Compression STYLE 15 or 20 <br /> 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED <br /> Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON <br /> 6* I <br /> 5 7/16" <br /> (11,1 mm) <br /> 4 NOMINAL 2" 0 (I I <br /> MAKE-IN (50,8 mm) <br /> 2 2" -3/8 m <br /> 3 (50,8 mm) (34,9 mm) <br /> WRENCH <br /> I FLATS <br /> 1 <br /> 1/2 NPT** DEFLECTOR* �— 2-7/8"(73,0 mm)DIA. <br /> CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT <br /> FIGURE 1 <br /> SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS <br /> 5.6 K-FACTOR, 112 INCH NPT, QUICK RESPONSE <br /> Installation Step 2. With pipe-thread sealant <br /> applied to the pipe threads, hand- <br /> /A The TYCO Series TY-FRB,5.6 K-factor, tighten the sprinkler into the sprinkler <br /> WRENCH RECESS Upright (TY313) and Pendent (TY323) fitting. <br /> (USE ONLY Sprinklers must be installed in accor- Step 3. Tighten the sprinkler into the <br /> END"A") dance with this section. sprinkler fitting using only the W Type <br /> General Instructions 6 Sprinkler Wrench(Figure 2).With ref- <br /> FIGURE 2 Do not install any bulb-type sprinkler erence to Figure 1,apply the W Type 6 <br /> W-TYPE 6 if the bulb is cracked or there is a loss Sprinkler Wrench to the wrench flats. <br /> SPRINKLER WRENCH of liquid from the bulb.With the sprin- Torque sprinklers 7 to 14 ft.-Ibs.(9,5 to <br /> kler held horizontally,a small air bubble 19,0 Nm). <br /> should be present.The diameter of the Recessed Pendent Sprinklers <br /> WRENCH air bubble is approximately 1/16 inch The Series TY-FRB Recessed Pendent <br /> RECESS (1,6 mm)for the 135°F(57°C) and 3/32 Sprinklers must be installed in accor- <br /> inch(2,4 mm)for the 286°F(141°C)tem- dance with the following instructions. <br /> perature ratings. <br /> � A leak-tight 1/2 inch NPT sprinkler Step A. After installing the Style 15 <br /> g p or Style 20 Mounting Plate over the <br /> joint should be obtained by applying a sprinkler threads,and with pipe-thread <br /> minimum to maximum torque of 7 to 14 sealant applied to the pipe threads, <br /> ft.-Ibs. (9,5 to 19,0 Nm). Higher levels hand-tighten the sprinkler into the <br /> of torque can distort the sprinkler Inlet sprinkler fitting. <br /> with consequent leakage or impairment <br /> PUSH WRENCH of the sprinkler. Step B. Tighten the sprinkler into the <br /> IN TO ENSURE sprinkler fitting using only the W Type <br /> ENGAGEMENT Do not attempt to compensate for 7 Recessed Sprinkler Wrench (Figure <br /> WITH SPRINKLER insufficient adjustment in the Escutch- 3).With reference to Figure 1,apply the <br /> WRENCHING AREA eon Plate by under-or over-tightening W Type 7 Recessed Sprinkler Wrench <br /> the sprinkler. Re-adjust the position of to the sprinkler wrench flats. Torque <br /> FIGURE 3 the sprinkler fitting to suit. sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 <br /> W-TYPE 7 RECESSED Upright and Pendent Sprinklers Nm). <br /> SPRINKLER WRENCH The Series TY-FRB Upright and Step C. After ceiling installation and <br /> Pendent Sprinklers must be installed finishing,slide on the Style 15 or Style <br /> in accordance with the following 20 Closure over the Series TY-FRB <br /> instructions. Sprinkler and push the Closure over the <br /> Step 1.Install Pendent sprinklers in the Mounting Plate until its flange comes in <br /> pendent position. Install upright sprin- contact with the ceiling. <br /> klers in the upright position. <br />