Laserfiche WebLink
Manual S Compliance Report Job: R0617216 <br /> - - wrightaofir p P, Date: 053047 <br /> Entire House By: JND <br /> Bahr's Propane Gas&AC Inc <br /> 4441 Allen Rd,Zeptwhlls,FL33541 Phone:813-782-5013 <br /> Project • • <br /> For: Lantman Residence <br /> Zephyrhills,FL <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 24956 Btuh Entering coil DB: 79.8°F <br /> Outdoor design WB: 77.3°F Latent gain: 4821 Btuh Entering coil WB: 64.6°F <br /> Indoor design DB: 75.0°F Total gain: 29777 Btuh <br /> IndoorRH: 50% Estimated airflow: 1140 cftn <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer. Franklin or Eqv Model: GSZ160361 B+ASPT37C14A <br /> Actual airflow: 1140 cfm <br /> Sensible capacity: 24966 Btuh 100%of load <br /> Latent capacity: 9234 Btuh 192%of load <br /> Total capacity: 34200 Btuh 115%of load SHR: 73% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.5°F Heat loss: 18701 Btuh Entering coil DB: 69.2°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer. Franklin or Eqv Model: GSZ160361 B+ASPT37C14A <br /> Actual airflow: 1140 cfm <br /> Output capacity: 35000 Btuh 187%of load Capacity balance: 27 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elecstrip <br /> Manufacturer. Model: <br /> Actual airflow: 1140 cfm <br /> Output capacity: 8.0 kW 146%of load Temp.rise: 22 °F <br /> Meets are all requirements ofACCA Manual S. <br /> 2017-May-3015:53:19 <br /> wrightsOft� Right SuteOUriversa1201717.0.10 RSU07440 Page 1 <br /> A+CK C:WVAClawork91MR0517216-Lartrnan\R0517216.nip Calc=MJ8 BuldingFrortfaces:N <br />