My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-18845
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-18845
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 8:31:28 AM
Creation date
9/18/2019 10:32:02 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-18845
Building Department - Name
LANTMAN,EDWARD & BONNIE
Address
5627 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project S Job: R0517216 <br /> ft° Summary-�- wrightso ry Date: 053047 <br /> Entire House By- JND <br /> Bahes Propane Gas&AC Inc <br /> 4441 AIIen Rd,ZepftAlls,FL33541 Phone:813-782-5013 <br /> Project • • <br /> For: Lantman Residence <br /> Zephyrhills,FL <br /> Notes: Load Calculation was obtained from an on-site inspection. <br /> Design Information <br /> Weather: Tampa IntemationalAP,FL,US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 OF. Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 28 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 grAb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 15037 Btuh Structure 15855 Btuh <br /> Duds 3664 Btuh Ducts 6285 Btuh <br /> Central vent(0 cFm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 2816 Btuh <br /> Piping 0 Btuh <br /> Equipment load 18701 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 24956 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 3227 Btuh <br /> Duds 1594 Btuh <br /> Heating Cooling Central vent(0 cfm) 0 Btuh <br /> Area 1268 1268 Equipment latent load 4821 Btuh <br /> Volume(iF) 11414 11414 <br /> Air changesthour 0.45 0.23 Equipmenttotal load 29777 Btuh <br /> Equiv AVF(cim) 86 44 Req.total capacity at 0.73 SHR 2.8 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Franklin or Eqv Make Franklin or Eqv <br /> Trade Split HP Trade Split HP <br /> Model GSZ160361 B Cond GSZ160361 B <br /> AHRI ref -8331282 Coil ASPT37C14A <br /> AHRI ref 8331282 <br /> Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER <br /> Heating input Sensible cooling 24966 Btuh <br /> Heating output 35000 Btuh @ 47°F Latent cooling 9234 Btuh <br /> Temperature rise 28 OF Total cooling 34200 Btuh <br /> Actual airflow 1140 cfm Actual airflow 1140 cfm <br /> Air flow factor 0.061 cfm/Btuh Air flow factor 0.051 cf Tdith <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.84 <br /> Capacity balance point=27 OF <br /> Backup: Aux Heat <br /> Input=8 kW, Output=27297 Btuh,100AFUE <br /> Calculations approved byACCAto meet all requirements of Manual J 8th Ed. <br /> 2017-May-3015:53:19 <br /> Ak WrIghtsoft` Rgri-sate®Uriversa1201717.0.10RSU07440 Pagel <br /> Zdk C:WVAC\aWorkFile1R0517216-Lantman1R0517216.np Calc=MA Bulding Front faces:N <br />
The URL can be used to link to this page
Your browser does not support the video tag.