Section <br /> # Mechanical Rough-In Inspection Complies? Comments/Assumptions <br /> &Re .ID <br /> C4'01-2.9. `Cavities in framed spaces are not ;❑Complies !Requirement will be met. <br /> 4:' used to deliver air from or return air to ❑Does Not <br /> ;[ME78]2 )the conditioning system unless they ; <br /> contain an air duct insert which is ;❑Not Observable <br /> insulated in accordance with Section []Not Applicable <br /> C403.2.9.1 and constructed and ; <br /> ,sealed in accordance with the <br /> requirements of Section C403.2.9.2 <br /> appropriate for the duct materials ; <br /> used. <br /> C403.2.9. Air distribution systems are sized and ;❑Complies ;Requirement will be met. <br /> 5, 3designed in accordance with ;❑Does Not <br /> [ME76]2 recognized engineering standards. <br /> 'Refer to section details. :❑Not Observable <br /> !,[]Not Applicable ; <br /> C403.2.9. Air-handling units not installed in ;❑Complies ;Requirement will be met. <br /> 6 attics of commercial buildings. ;❑Does Not <br /> [ME77]2 UNot Observable; <br /> ❑Not Applicable <br /> C408�2 2.; Air system balancing accomplished in ;❑Complies ;Requirement will be met. <br /> 1- = a manner to first minimize throttling :❑Does Not <br /> losses,then for fans with fan system <br /> <' power greater than 1 hp,fan speeds UNot Observable: <br /> " = shall be adjusted to meet design flow ❑Not Applicable ; <br /> ., <br /> conditions. Balancing procedures shall <br /> be in accordance with NEBB <br /> *jt ,M Procedural Standards,the AABC, <br /> ° National Standards, i ore equivalent q , <br /> procedures. ; <br /> C403.2.6. !Demand control ventilation provided ;❑Complies ;Requirement will be met. <br /> 1 ;for spaces>500 ft2 and >25 :❑Does Not <br /> [ME59]1 i people/1000 ft2 occupant density and ; ; <br /> ;served by systems with air side UNot Observable <br /> economizer, auto modulating outside ;❑Not Applicable ; <br /> air damper control,or design airflow <br /> >3,000 cfm. ; <br /> `G403>267°= Enclosed parking garage ventilation ;❑Complies ;Exception: Requirement does not apply. <br /> Z 2 "_. has automatic contaminant detection ;❑Does Not <br /> [MmEt115 ; and capacity to stage or modulate ; <br /> fans to 50%or less of design capacity.;❑Not Observable, <br /> g ❑Not Applicable , <br /> C403.2.7 M Exhaust air energy recovery on !❑Complies :Exception: Requirement does not apply. <br /> [ME57]1 systems meeting Table C403.2.7(1) ;❑Does Not ; <br /> ;and C403.2.7(2). UNot Observable: <br /> F ;❑Not Applicable <br /> 403 - µ Kitchen exhaust systems comply with ;❑Complies ;Exception: Requirement does not apply. <br /> [MEal7;6]3" replacement air and conditioned :❑Does Not . <br /> supply air limitations, and satisfy hood <br /> rating requirements and maximum UNot Observable; <br /> ' exhaust rate criteria. ;❑Not Applicable ; <br /> Jt6A <br /> Multiple zone VAV systems with DDC ;❑Complies ;Exception: Requirement does not apply. <br /> of individual zone boxes have static ;❑Does Not <br /> pressure setpoint reset controls. :See the Mechanical systems list for values. <br /> ❑Not Observable❑Not Applicable <br /> Multiple zone VAV systems with DDC. ;❑Complies ;Exception: Requirement does not apply. <br /> of individual zone boxes have static ;❑Does Not <br /> pressure setpoint reset controls. ;❑Not Observable;See the Mechanical Systems list for values. <br /> ;❑Not Applicable <br /> 1 High Impact(Tier 1) 2 Medium Impact(Tier2) .3 Low Impact(Tier 3) <br /> Project Title: Zephyrhills Dental Building Report date: 02/13/19 <br /> Data filename: D:\Hill Foley Rossi\Heartland Dental\Zephyrhills, FL\Heartland Zephyrhills Comcheck.cck Page 8 of 13 <br />