My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21125
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21125
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 11:09:01 AM
Creation date
1/7/2020 11:08:59 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21125
Building Department - Name
LENNAR HOMES LLC
Address
35893 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE-FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2277B sf ADS Carrier VW Builder Name: Lennar Homes 0527 <br /> Street: 3=Saddle Palm Way 3SVS Permit office: City of Ze' hyrhills <br /> City,State,Zip: FL, Permit Number: 24 1 <br /> Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1672.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1314.70 ftz <br /> b.Frame-Wood,Exterior R=11.0 234.67 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 122.67 ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2278.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2278.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2278 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(197.8 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 455.6 <br /> a. U-Factor: Dbl,U=0.33 125.85 ft2 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 35.0 SEER:15.50 <br /> c. U-Factor: Dbl,U=0.33 32.00 ft2 <br /> SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.065 ft. <br /> Area Weighted Average SHGC: 0.249 14.Hot water systems <br /> 8. Floor Types (2278.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 2278.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.087 Total Proposed Modified Loads: 63.67 PASS <br /> Total Baseline Loads: 67.23 <br /> I hereby certify that the plans and specifications covered by Review of the plans andTkXE.STg7; <br /> this calculation are in compliance with the Florida Energy specifications covered by this O ' ` 0 <br /> .Code. calculation indicates compliance <br /> /' till .with the.Florida Energy Code. �+ ifiii <br /> PREPARED BY: Dave AulicGt Before construction is completed <br /> DATE: this buildingwill be inspected for <br /> P C7 :'`'af <br /> compliance with Section 553.908 <br /> I hereby certify that this buildin s designed, is in compliance Florida Statutes. : <br /> with the Florida Energy Code. G'Op` ��,. <br /> OWNER/AGENT: MAR 9 2 2019 BUILDING OFFICIAL: <br /> DATE: DATE: MAK <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. <br /> 3/7/2019 2:41 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.