Laserfiche WebLink
Alternator data <br /> Standard Alternators Single phase2 Three Phase' <br /> Maximum temperature rise above 40°C .125'C 125°C <br /> ambient <br /> Feature code BB90-2 B946-2 B986-2 B952-2 B943-2 BB86-2 <br /> Alternator data sheet number ADS-213 ADS-213 ADS-212 ADS-212 ADS-211 ADS-212 <br /> Voltage ranges 120/240 120/208 120/240 347/600 277/480 127/220 <br /> Voltage feature code R104-2 R098-2 R106-2 R114-2 R002-2 R020-2 <br /> Surge kW 205.7 211.1 213.4 1 214.3 213.4 211.6 <br /> Motor starting kVA(at 90%sustained 770 770 672 770 672 770 <br /> voltage)Shunt <br /> Motor starting kVA(at 90%sustained 920 920 791 920 791 920 <br /> voltage)PMG <br /> Full load current amps at standby rating 833 694 602 240 301 656 <br /> Alternator data <br /> Standard Alternators Three phase' <br /> Maximum temperature rise above 40°C 105 °C 105 °C 105 °c 105 °C 105 °C <br /> ambient <br /> Feature code BB94-2 BB95-2 BB92-2 BB85-2 BB93-2 <br /> Alternator data sheet number ADS-212 ADS-212 ADS-212 ADS-212 ADS-213 <br /> Voltage ranges 120/240 277/480 347/600 127/220 120/208 <br /> Voltage feature code R106-2 R002-2 R114-2 R020-2 R098-2 <br /> Surge kW 213.4 213.4 214.3 211.6 211.1 <br /> Motor starting kVA(at 90%sustained 770 770 770 770 770 <br /> voltage)Shunt <br /> Motor starting kVA(at 90%sustained 920 920 920 920 920 <br /> voltage)PMG <br /> Full load current amps at standby rating 602 301 240 656 694 <br /> Notes: <br /> 1 Single phase power can be taken from a three phase generator set at up to 213 set rated 3-phase kW at 1.0 power factor <br /> 2 Full single phase output up to full set rated 3-phase kW at 1.0 power factor <br /> Formulas for calculating full load currents: <br /> TFijee.phase output Single phase output <br /> kW x 1000 kW x SinglePhaseFactor x 1000 <br /> Voltage x 1.73 x 0.8 Voltage <br /> Warning:Back feed to a utility system can cause electrocution and/or property damage.Do not connect to any building's electrical system <br /> except through an approved device or after building main switch is open. <br /> North America <br /> 1400 73rd Avenue N.E. <br /> Minneapolis,MN 55432 <br /> USA <br /> Phone 763 574 5000 <br /> Fax 763 574 5298 <br /> Our energy working for yoWl <br /> ©2019 Cummins Inc.All rights reserved. <br /> Cummins is a registered trademarks of Cummins Inc.PowerCommand,AmpSentry,InPower <br /> and"Our energy working for you.'are trademarks of Cummins.Other company,product,or service names <br /> may be trademarks or service marks of others.Specifications are subject to change without notice. power.cummins.com <br /> NAD-6374-EN(01119)A061 F589 <br />