19-21222
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21222
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2020 10:27:03 AM
Creation date
1/8/2020 10:26:52 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS
Building Department - Doc Type
Permit
Permit #
19-21222
Building Department - Name
FITZGERALD,CF & LIV TRUST
Address
6320 SILVER OAKS DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 1: <br /> Design Pressure(DP)and Anchor QuallUfles Required, <br /> (tor all approved configurations on Sheet 2) <br /> Use this labia for. Door Unit Height ANCHORAGE TYPE PER SUBSTRATE REQUIRED TO ACHIEVE THE DESIGN <br /> PRESSURE,USING THE ANCHOR QUANTIFS LISTED BELOW.SEE TABLE A, <br /> Glass Types 1,1A,3 or 3A 80" 84" 96" /SHEET 1 FOR COMPLETE ANCHOR LIMITATIONS. <br /> Astragal Reinforcement#29 68-15116"DLO Height 72-15f16"DLO Height 84-15/16"DLO Height THE MAXIMUM DP AT THESE ANCHOR QUANTITIES.ADDITIONALLY,THE <br /> Locl ile Reinforcement#25 or#26 Anchor Group Anchcr Group Anchor Group MAXIMUM POSITIVE DP DUE TO THE SILL HEIGHT MUST ALSO BE <br /> Std.Interiock Reinforcement#27 A B C D A B C D A B C D CONSIDERED,SEE TABLE B1,THIS SHEET. <br /> Design Pressure +601.60 psf +60/-60psf +601-60 psf #OF ANCHORS THROUGH THE HEAD&SILL.(EX:FOR C3+1,3 ANCHORS <br /> f2— <br /> Head/Sill C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 c3+1 c3+1 CLUSTERED AT PANEL MEETING POINT AND 1 ANCHOR REQUIRED AT <br /> Jamb 5 5 5 5 5 5 5 5 .5 5 5 5 MIDSPAN OF PANEL). <br /> -�TOTAL#OF ANCHORS THROUGH THE JAMB. <br /> P hook T 7 7 7 7 T 7 7 8 8 8 B <br /> Design Pressure +60/•fi0psf +60/-60psf +60/-60psf `THE#OF ANCHORS REQUIRED THROUGH THEP-HOOK <br /> Head/Slll C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1PERPENDICULAR TO THE GLASS. <br /> ,lamb 5 5 5 5 5 5 5 5 5 5 5 6 <br /> P41ook 77 7 7 7 7 8 8 8 8 <br /> Design Pressure +60/-60psf +60 -60psf +60/-60ps1 Head/SUI C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 <br /> .9 1 Jamb 5 5 5 5 5 6 6 5 5 5 5 5 <br /> Width P-hook 7 7 7 7 7 7 7 7 6 B 8 8 <br /> o Design Pressure +60/-60 psf +60/-60 psf +60/-60 psf <br /> Z 37--1/8" _ <br /> 42" DLO I lead/SIII C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 TABLE B1: <br /> Width Jamb 5 5 5 5 5 5 6 5 5 5 5 5 Water-Limited <br /> FIG 1: <br /> P•hook 7 1 7 7 7 7 7 7 7 6 B 6 B (+)Design Pressure OH LENGTH <br /> Design Pressure +60/-60psf +60/-60psf +60/-60psf Sill Nom.Sill Max.(+)DP <br /> 43.1/8 Head/Sill C3+2 C3+1 C3+1 C3+1 C3+2 C3+1 C3+1 C3+1 C5+2 C3+1 C3+1 C3+1 <br /> Riser Height Allowed F DOORASSEMBLIES <br /> 48 Width Jamb 5 5 5 5 5 5 5 5 5 5 6 5 one 1-11/16" See Note2 INSTALLED WHERE THE PRODUCT REVISED <br /> P hook 7 7 7 7 7 7 7 7 6 8 8 8 W OVERHANG(OH)LENGTH IS as complying with the Florida <br /> 42 2-112" +3S.7 psF s EQUAL TO OR GREATER THAN Bulimng Cade <br /> 43 3.1/2" +610 psf p THE OVERHANG HEIGHT IS Ni 17-0420.06 <br /> USED IN EXAMPLE ON SHEET 0 44 4-11161 +60.0 psf EXEMPTED FROM WATER Explrathm Date 04114/2021 <br /> 45 45/8" +60.0 psf INFILTRATION RESISTANCE. By <br /> _ Nuarm-ui product control <br /> r <br /> DLO WIDTH=NOM.PANEL WIDTH-8-9116" `` �11YlLYNrrr <br /> DLO HEIGHT=DOOR HEIGHT-11-1/16" �%� rrr <br /> PANEL HEIGHT=DOOR HEIGHT-2-1/2' SON••• ' i <br /> dal ltcerus� �!!�% <br /> TABLE NOTES: ' <br /> A,VINYL SLIDING GLASS DOOR NOA(LM) 2 10/05/15 ',f No.58705' <br /> 1)IF WATER INFILTRATION RESISTANCE IS REQUIRED,THE LESSER VALUES OF EITHER TABLE 1 --- "-_ <br /> AND TABLE B1 DETERMINES THE WATER LIMITED(+)DP. o DP&ANCHOR QUANTITY TABLE J ROSOWSKI .G } ; <br /> 2)IF WATER INFILTRATION RESISTANCE IS NOT REQUIRED OR OVERHANG IS PER FIG 1,A SILL - <br /> RISER IS NOT REQUIRED.IF SO,+DP'S SHOWN IN TABLE 1 MAY BE USED. COMIGHr02017 POT Ni INC. NO CHANGES THIS SHEET. 04/05/17 i��t`' `YOflIDP,.•'1= � <br /> 3)SEE SILL RISER TYPES ON SHEET 4. _ALL RIGHTS RESERVED �i�5'S ••••- NC9�` <br /> 4)SHEET APPLIES TO 2,3 AND 4.TRACK CONFIGURATIONS. 1070 TECHNOLOGY DR Y "�.r10NAL V�`�� <br /> N.VENICE,FL 34275 rr/h i l l ox <br /> 5)REFER TO ANCHOR NOTES,SHEET 1. (941)-480-1600 d A.LYNN MILLER,P.E <br /> 6)SEE SHEETS 11-16 FOR ANCHOR LOCATION&SPACING cenT o�Auni aeszae SGD5570 NTS 1 7 OF 21 z MD-5570.0 e A P.N WILLIes <br />