My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21222
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21222
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2020 10:27:03 AM
Creation date
1/8/2020 10:26:52 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS
Building Department - Doc Type
Permit
Permit #
19-21222
Building Department - Name
FITZGERALD,CF & LIV TRUST
Address
6320 SILVER OAKS DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 2: _.. <br /> Design Pressure(DP)and Anchor Quantities Required, <br /> (for all approved configurations on Sheet 2) ANCHORAGE TYPE PER SUBSTRATE REQUIRED TO ACHIEVE THE DESIGN <br /> Use this table for. Door Unit I[eight PRESSURE,USING THE ANCHOR QUANTIES LISTED BELOW:SEE TAB[-E A, <br /> Glass Types 2 or 4 80" 84' 96" 108" 120' SHEET 1 FOR COMPLETE ANCHOR LIMITATIONS. <br /> Astragal Reinforcement#29 68-15116"DLO Height 72-15116'DLO Height 84-15116"DLO Height 96-15116"DLO Height 108-15116°OLD Height THE MAXIMUM DP AT THESE ANCHOR QUANTITIES.ADDITIONALLY,THE <br /> Lockstile Reinforcement#25 Anchor Group Anchor Group Anchor Group Anchor Group Anchor Group MAXIMUM POSITIVE DP DUE TO THE SILL HEIGHT MUST ALSO BE <br /> HD Interlock Reinforcement#28 A B C D A B C D A e C D A B C D A B C 0 /CONSIDERED,SEE TABLE B2,THIS SHEET. <br /> DesgnPrsssue +100/-100psf +1001-100psf +100/-100psf +60/-65psf +60/-65psf #OF ANCHORS THROUGH THE HEAD&SILL.(EX:FOR C3+1,3ANCHORS <br /> Head/Slil C3+1 C3+1 =1��G3+1 <br /> +1 C3+1 C3+1 C5+1 C3+1 C3+1 C3r1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 CLUSTERED AT PANEL MEETING POINT AND 1 ANCHOR REQUIRED AT <br /> 24° DLO Jamb 5 5 5 5 5 5 5 5 8 6 6 8 6 6 g 6 MIDSPAN OF PANEL). <br /> Width TOTAL 0 OF ANCHORS THROUGH THE JAMB. <br /> P-hook 7 7 7 7 8 8 e 8 9 9 9 9 10 10 10 10 THE#OF ANCHORS REQUIRED THROUGH THE P-HOOK, <br /> Design Pressure +100/-10/-100psf +100/-f00psf +601-65psf +60/-65psf PERPENDICULAR TO THE GLASS.25-1/8" Head/SIII C5+1 C3+1 +1 C3+1 C3+1 05+1 C3+1 C5+1 C3+1 C3+1 C3+1 C3+1-C3+1 C5+1 C3+1 C3+1 C3+1 <br /> 30" DLO Jamb 5 5 6 5 5 5 7 5 B 6 6 8 8 8 6 6 <br /> Width <br /> P-hock 7 7 7 7 7 7 7 7 8 8 B 6 9 9 9 9 10 10 10 10 <br /> DeslgnPressure +100/-100psf +100/-100psf +fool-100psf +60/-65psf +60/-65psf FIG <br /> 31-1/8° Head/Sill G5+2 C3+1 C5+1 C3+1 C5+2 1 C3+1 C5+1 03+1 05+2 05+1 C5+1 C3+1 C5+1 C3+1 C3+1 C3+1 C5+1 C3+1 C5+1 C3+1 OH LENGTH~ <br /> 36" DLO Jamb 5 5 6 5 5 5 6 5 - 5 5 7 5 8 B 8 6 6 6 6 <br /> = Width <br /> Phook 7 7 7 7 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 H DOOR ASSEMBLIES <br /> § Design Pressu a +100/-f00 psf +100/-100 psf +100/400 psf +601-65 psf +60/-65 psf 0 INSTALLED WHERE THE <br /> 37.1/8" <br /> Head/Sill C5+2 C3+2 C5+2 C3+1 C5+2 C5+2 C5+2 C3+1 C5+2 C5+2 C5+2 C3+1 C5+1 C3+1 C5+1 C3+1 C5+1 C5+1 C6+1 C3+1 to OVERHANG O E S <br /> a 42" OLD I EQUAL TO OR GREATER THAN <br /> Width Jamb 5 5 7 5 5 5 7 5 5 5 8 5 11 6 6 8 8 8 7 6 O THE OVERHANG HEIGHT IS <br /> P-hook 7 7 1 7 1 7 7 7 7 7 8 ' 8 8 8 9 9 9 1 9 10 10 1 10 10 EXEMPTED FROM WATER <br /> Z DesignPresswe +100/-100psf +100/-100psf +92/-92psf" +60/-65psf +60/-65psf INFILTRATION RESISTANCE. <br /> 43-118" Head/Sill C5+2 C5+2 C5+2 C3+2 C5+2 C5+2 C5+2 C3+2 C5+2 C5+2 G5+2 05+2 C5+2 C3+1 C5+2 C3+1 C5+2 C5+1 C5+2 C3+1 <br /> 48" DLO Jamb 5 5 7 5 5 5 1 8 1 5 5 5 9 1 5 6 6 7 6 6 1 6 8 6 <br /> Width PRODUCT REVISED <br /> P-hook 7 7 1 7 7 7 1 7 1 8 1 8 8 1 8 9 1 9 9 9 9 9 10 10 10 10 TABLE B2: <br /> Design Pressure +60/-80psf +80/-80psf +80/-80psf +60/65psf +54.1/•58.7losf Water-Limited as compsyIngwiththeFlorlda <br /> Building Code <br /> 49-1/8' Head/Sill C5+2 C3+2 C5+2 C3+2 C5+2 C3+2 C5+2 C3+2 C5+2 C5+2 C5+2 C3+2 E+2 C5+2 C5+2 C5+2 C5+2 M2 C5+2 C5+2 (+)Design Pressure NOA No, 17-0420.06 <br /> W, DLO Expiration Date 04/14/2021 <br /> Width Jamb 5 5 6 5 5 5 7 5 5 5 8 5 6 6 8 6 8 B 8 6 S81 NHei Sill MAX.(+)DP <br /> P-hook 7 7 7 7 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 90 Riser Height Allowed By <br /> +80/-80 +60/-W +59.1/-64 +49.6/-53.7 f None 1-11116" Sea Note 2 Ngn r Prodncttonerol <br /> Design P/esstae +80/-80 psf - psf psf psf ps <br /> 55-1/8" Head/Sill G5+3 C3+2 C5+3 C3+2 C5+3 C3+2 C5+3 C3+2 CS+3 C5+2 C5+3 C3+2 C5+2 C5+2 C5+2 C5+2 C5+2 C5+2 C5+2 C5+2 42 2-112" +38.7 psf <br /> 60" DLO Jamb 5 5 6 5 5 5 7 6 5 5 8 5 8 6 8 6 6 6 8 8 43 3.1/2' +60.0 psf <br /> Width <br /> P-hook 7 7 7 7 7 7 7 7 8 8 e 8 9 9 9 9 1D 10 10 10 44 41/16 +SO.O psf <br /> •+1-100.0 PSF FOR ANCHOR GROUPS B,C&D. 45 4-518' +100.0 psf <br /> DLO WIDTH=NOM.PANEL WIDTH-8-9116' \vvv r� <br /> DLOHEIGHT=DOOR HEIGHT-11-1/16" `� ONYLYIV/y� zip <br /> PANEL HEIGf n=DOOR HEIGHT--2 1/2" 4=��•'Lvcr-.HSF'•�1��� <br /> TABLE NOTES: =*:r No.58705 <br /> VINYL SLIDING GLASS DOOR NOA(LM) 10/05/15 <br /> 1)IF WATER INFILTRATION RESISTANCE IS REQUIRED,THE LESSER VALUES OF EITHERTABLE 2 0? a✓= <br /> AND TABLE B2 DETERMINES THE WAFER LIMITED(+)OR DP&ANCHOR QUANTITY TABLE m^ J ROSOWSKI �130, 5TATEg <br /> 2)IF WATER INFILTRATION RESISTANCE IS NOT REQUIRED OR OVERHANG IS PER FIG 1,A SILL e n •- <br /> RISER IS NOT REQUIRED.IF SO,+DP'S SHOWN IN TABLE 2 MAY BE USED. corvrsiaer®soft voriNovsrwes,mc. a NO CHANGES THIS SHEET. 04/05/17 '��5+'F��R... <br /> 3)SEE SILL RISER TYPES ON SHEET 4. nu moNrsraEsetvEo ���`S/01VAI- <br /> E���� <br /> 4)SHEET APPLIES TO 2,3 AND 4 TRACK CONFIGURATIONS. 1 N.VENT HNIOLE FL GY 6R c �� rr r r r r i l t t tvv v <br /> 5)REFER TO ANCHOR NOTES,SHEET 1. <br /> 6)SEE SHEETS 11-16 FOR ANCHOR LOCATION 8 SPACING (941)-480.1600 SGD-5570 NTS 8 OF 21 0 MD-5570.0 z A A.LYNN MILLER,987(19 .E <br /> CERT.oFAem F=s[[90 w P.FJl5a7r15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.